SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-269002"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-269002" > A new index for cha...

A new index for characterizing micro-bead motion in a flow induced by ciliary beating : Part II, modeling.

Bottier, Mathieu (författare)
Eq. 13, Institut Mondor de Recherche Biomédicale, Inserm U955, Créteil, France
Peña Fernández, Marta (författare)
Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, PO1 3DJ, UK
Pelle, Gabriel (författare)
Eq. 13, Institut Mondor de Recherche Biomédicale, Inserm U955, Créteil, France
visa fler...
Isabey, Daniel (författare)
Eq. 13, Institut Mondor de Recherche Biomédicale, Inserm U955, Créteil, France
Louis, Bruno (författare)
Eq. 13, Institut Mondor de Recherche Biomédicale, Inserm U955, Créteil, France
Grotberg, James B (författare)
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
Filoche, Marcel (författare)
Eq. 13, Institut Mondor de Recherche Biomédicale, Inserm U955, Créteil, France
visa färre...
Eq 13, Institut Mondor de Recherche Biomédicale, Inserm U955, Créteil, France Zeiss Global Centre, School of Mechanical and Design Engineering, University of Portsmouth, Portsmouth, PO1 3DJ, UK (creator_code:org_t)
2017-07-14
2017
Engelska.
Ingår i: PloS Computational Biology. - : Public Library of Science (PLoS). - 1553-734X .- 1553-7358. ; 13:7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Mucociliary clearance is one of the major lines of defense of the human respiratory system. The mucus layer coating the airways is constantly moved along and out of the lung by the activity of motile cilia, expelling at the same time particles trapped in it. The efficiency of the cilia motion can experimentally be assessed by measuring the velocity of micro-beads traveling through the fluid surrounding the cilia. Here we present a mathematical model of the fluid flow and of the micro-beads motion. The coordinated movement of the ciliated edge is represented as a continuous envelope imposing a periodic moving velocity boundary condition on the surrounding fluid. Vanishing velocity and vanishing shear stress boundary conditions are applied to the fluid at a finite distance above the ciliated edge. The flow field is expanded in powers of the amplitude of the individual cilium movement. It is found that the continuous component of the horizontal velocity at the ciliated edge generates a 2D fluid velocity field with a parabolic profile in the vertical direction, in agreement with the experimental measurements. Conversely, we show than this model can be used to extract microscopic properties of the cilia motion by extrapolating the micro-bead velocity measurement at the ciliated edge. Finally, we derive from these measurements a scalar index providing a direct assessment of the cilia beating efficiency. This index can easily be measured in patients without any modification of the current clinical procedures.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy