SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:kth-45593"
 

Sökning: onr:"swepub:oai:DiVA.org:kth-45593" > Temporal frequency ...

Temporal frequency requirements for tissue velocity imaging of the fetal heart

Elmstedt, Nina (författare)
KTH,Medicinsk teknik
Lind, Britta (författare)
KTH,Medicinsk teknik
Ferm-Widlund, K. (författare)
visa fler...
Westgren, M. (författare)
Karolinska Institutet
Brodin, Lars-Åke (författare)
KTH,Medicinsk teknik
visa färre...
 (creator_code:org_t)
2011-09-20
2011
Engelska.
Ingår i: Ultrasound in Obstetrics and Gynecology. - : Wiley. - 0960-7692 .- 1469-0705. ; 38:4, s. 413-417
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives The high velocity and short duration of myocardial motion requires a high sampling rate to obtain adequate temporal resolution; this issue becomes even more important when taking into consideration the high fetal heart rate. In this study we have established optimal sampling requirements for assessing the duration of various cardiac cycle events and myocardial velocities of the fetal heart using color-coded tissue velocity imaging (TVI). Methods Recordings from 30 fetuses were acquired at an initial frame rate of 180-273 frames/s. All TVI recordings were performed from an apical four-chamber view and stored as cineloops of five to 10 consecutive cardiac cycles for subsequent offline analysis using software enabling a reduction in frame rate. Different components of the myocardial velocity curve, obtained from the basal part of the ventricular septum, were measured at the initial frame rate and compared with their equivalents at gradually decreased frame rates. Results As acquisition frame rate was reduced, there was a marked increase in deviation from the initial values, resulting in an underestimation of all systolic and diastolic velocities. For the measured durations, there was a clear tendency to underestimate isovolumetric contraction and relaxation, and a clear tendency to overestimate ventricular ejection and diastolic E-wave and A-wave. An acceptable <= 5% deviation from the value obtained at the highest frame rate corresponded to measurements obtained at above 150-200 frames/s. Conclusions A high sampling rate of at least 200 frames/s is necessary for adequate reconstruction of TVI data for the fetal heart. Frame rates that are too low result in considerable loss of temporal and velocity information.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

fetal echocardiography
frame rate
sampling frequency
temporal frequency requirements
tissue velocity imaging

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy