SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-13042"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-13042" > Assessing Aortic St...

Assessing Aortic Stenosis using Sample Entropy of the Phonocardiographic Signal in Dogs

Ahlström, Christer (författare)
Linköpings universitet,Fysiologisk mätteknik,Hälsouniversitetet
Höglund, Katja (författare)
Hult, Peter (författare)
Linköpings universitet,Fysiologisk mätteknik,Hälsouniversitetet
visa fler...
Häggström, Jens (författare)
Kvart, Clarence (författare)
Ask, Per (författare)
Linköpings universitet,Fysiologisk mätteknik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2008
2008
Engelska.
Ingår i: IEEE Transactions on Biomedical Engineering. - 0018-9294 .- 1558-2531. ; 55:8, s. 2107-2109
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In aortic valve stenosis (AS), heart murmurs arise as an effect of turbulent blood flow distal to the obstructed valves. With increasing AS severity, the flow becomes more unstable, and the ensuing murmur becomes more complex. We hypothesize that these hemodynamic flow changes can be quantified based on the complexity of the phonocardiographic (PCG) signal. In this study, sample entropy (SampEn) was investigated as a measure of complexity using a dog model. Twenty-seven boxer dogs with various degrees of AS were examined with Doppler echocardiography, and the peak aortic flow velocity (Vmax) was used as a reference of AS severity. SampEn correlated to Vmax with R = 0.70 using logarithmic regression. In a separate analysis, significant differences were found between physiologic murmurs and murmurs caused by AS (p < 0.05), and the area under a receiver operating characteristic curve was calculated to 0.96. Comparison with previously presented PCG measures for AS assessment showed improved performance when using SampEn, especially for differentiation between physiological murmurs and murmurs caused by mild AS. Studies in patients will be needed to properly assess the technique in humans.

Nyckelord

Aortic stenosis (AS)
bioacoustics
heart sound
murmur
sample entropy (SampEn)
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy