Sökning: onr:"swepub:oai:DiVA.org:liu-132506" >
Untargeted screenin...
Untargeted screening of unknown xenobiotics and potential toxins in plasma of poisoned patients using high-resolution mass spectrometry: Generation of xenobiotic fingerprint using background subtraction
-
- Chen, Chang (författare)
- Huazhong University of Science and Technology, Peoples R China
-
- Wohlfarth, Ariane (författare)
- Linköpings universitet,Avdelningen för läkemedelsforskning,Medicinska fakulteten,National Board Forens Med, Linköping, Sweden
-
- Xu, Hui (författare)
- Maternal and Child Health Hospital Hubei Prov, Peoples R China
-
visa fler...
-
- Su, Dan (författare)
- Jiangxi University of Tradit Chinese Med, Peoples R China
-
- Wang, Xin (författare)
- MassDefect Technology, NJ 08540 USA
-
- Jiang, Hongliang (författare)
- Huazhong University of Science and Technology, Peoples R China
-
- Feng, Yulin (författare)
- Jiangxi University of Tradit Chinese Med, Peoples R China
-
- Zhu, Mingshe (författare)
- Bristol Myers Squibb, NJ 08543 USA
-
visa färre...
-
(creator_code:org_t)
- ELSEVIER SCIENCE BV, 2016
- 2016
- Engelska.
-
Ingår i: Analytica Chimica Acta. - : ELSEVIER SCIENCE BV. - 0003-2670 .- 1873-4324. ; 944, s. 37-43
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A novel analytical workflow was developed and applied for the detection and identification of unknown xenobiotics in biological samples. High-resolution mass spectrometry (HRMS)-based data-independent MSE acquisition was employed to record full scan MS and fragment spectral datasets of test and control samples. Then, an untargeted data-mining technique, background subtraction, was utilized to find xenobiotics present only in test samples. Structural elucidation of the detected xenobiotics was accomplished by database search, spectral interpretation, and/or comparison with reference standards. Application of the workflow to analysis of unknown xenobiotics in plasma samples collected from four poisoned patients led to generation of xenobiotic profiles, which were regarded as xenobiotic fingerprints of the individual samples. Among 19 xenobiotics detected, 11 xenobiotics existed in a majority of the patients plasma samples, thus were considered as potential toxins. The follow-up database search led to the tentative identification of azithromycin (X5), alpha-chaconine (X9) and penfluridol (X12). The identity of X12 was further confirmed with its reference standard. In addition, one xenobiotic component (Y5) was tentatively identified as a penfluridol metabolite. The remaining unidentified xenobiotics listed in the xenobiotic fingerprints can be further characterized or identified in retrospective analyses after their spectral data and/or reference compounds are available. This HRMS-based workflow may have broad applications in the detection and identification of unknown xenobiotics in individual biological samples, such as forensic and toxicological analysis and sport enhancement drug screening. (C) 2016 Elsevier B.V. All rights reserved.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
Nyckelord
- High-resolution mass spectrometry; Background subtraction; Untargeted data-mining; Unknown xenobiotics; Database search; Toxic chemicals