100a Gaillard, Francoisu Paris Descartes University, France4 aut
2451 0a Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors
264 c 2016-05-24
264 1b SPRINGER,c 2017
338 a print2 rdacarrier
520 a Screening of living kidney donors may require scintigraphy to split glomerular filtration rate (GFR). To determine the usefulness of computed tomography (CT) to split GFR, we compared scintigraphy-split GFR to CT-split GFR. We evaluated CT-split GFR as a screening test to detect scintigraphy-split GFR lower than 40 mL/min/1.73 m(2)/kidney. This was a monocentric retrospective study on 346 potential living donors who had GFR measurement, renal scintigraphy, and CT. We predicted GFR for each kidney by splitting GFR using the following formula: Volume-split GFR for a given kidney = measured GFR*[volume of this kidney/(volume of this kidney + volume of the opposite kidney)]. The same formula was used for length-split GFR. We compared length- and volume-split GFR to scintigraphy-split GFR at donation and with a 4-year follow-up. A better correlation was observed between length-split GFR and scintigraphy-split GFR (r = 0.92) than between volume-split GFR and scintigraphy-split GFR (r = 0.89). A length-split GFR threshold of 45 mL/min/1.73 m(2)/kidney had a sensitivity of 100 % and a specificity of 75 % to detect scintigraphy-split GFR less than 40 mL/min/1.73 m(2)/kidney. Both techniques with their respective thresholds detected living donors with similar eGFR evolution during follow-up. Length-split GFR can be used to detect patients requiring scintigraphy. aEuro cent Excellent correlation between kidney length and scintigraphy predicted GFR aEuro cent Kidney length screening detects all donors with GFR lower than 40 mL/min/1.73 m (2) aEuro cent Kidney length screening can replace scintigraphy screening.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a living donor; kidney; renal transplantation; CT; split renal function/split GFR
700a Pavlov, Patriku Linköpings universitet4 aut
700a Tissier, Anne-Marieu Paris Descartes University, France4 aut
700a Harache, Benoitu Paris Descartes University, France4 aut
700a Eladari, Dominiqueu Paris Descartes University, France; INSERM, France4 aut
700a Timsit, Marc-Olivieru Paris Descartes University, France4 aut
700a Fournier, Catherineu Paris Descartes University, France4 aut
700a Leon, Carineu Paris Descartes University, France4 aut
700a Hignette, Chantalu Paris Descartes University, France4 aut
700a Friedlander, Gerardu Paris Descartes University, France; INSERM, France4 aut
700a Correas, Jean-Michelu Paris Descartes University, France4 aut
700a Weinmann, Pierreu Paris Descartes University, France4 aut
700a Mejean, Arnaudu Paris Descartes University, France4 aut
700a Houillier, Pascalu Paris Descartes University, France; CNRS, France4 aut
700a Legendre, Christopheu Paris Descartes University, France4 aut
700a Courbebaisse, Marieu Paris Descartes University, France; INSERM, France4 aut
710a Linköpings universitetb Paris Descartes University, France4 org
773t European Radiologyd : SPRINGERg 27:2, s. 651-659q 27:2<651-659x 0938-7994x 1432-1084
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-134596
8564 8u https://doi.org/10.1007/s00330-016-4410-7

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy