Sökning: onr:"swepub:oai:DiVA.org:liu-139518" >
Amperometric L-argi...
Amperometric L-arginine biosensor based on a novel recombinant arginine deiminase
-
- Zhybak, Mykhailo T. (författare)
- National Academic Science Ukraine, Ukraine
-
- Fayura, Lyubov Y. (författare)
- NAS Ukraine, Ukraine
-
- Boretsky, Yuriy R. (författare)
- Lviv State University of Phys Culture, Ukraine
-
visa fler...
-
- Gonchar, Mykhailo V. (författare)
- NAS Ukraine, Ukraine
-
- Sibirny, Andriy A. (författare)
- NAS Ukraine, Ukraine; Rzeszow University, Poland
-
- Dempsey, Eithne (författare)
- ITT Dublin, Ireland
-
- Turner, Anthony (författare)
- Linköpings universitet,Biosensorer och bioelektronik,Tekniska fakulteten
-
- Korpan, Yaroslav I. (författare)
- National Academic Science Ukraine, Ukraine
-
visa färre...
-
(creator_code:org_t)
- 2017-05-02
- 2017
- Engelska.
-
Ingår i: Microchimica Acta. - : SPRINGER WIEN. - 0026-3672 .- 1436-5073. ; 184:8, s. 2679-2686
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
http://mural.maynoot...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- The authors describe an amperometric biosensor for the amino acid L-arginine (L-Arg). It is based on the use of a Nafion/Polyaniline (PANi) composite on a platinum screen-printed electrode (Pt-SPE) using a novel recombinant arginine deiminase isolated from Mycoplasma hominis. The protein was over-expressed, purified and employed as a biorecognition element of the sensor. Enzymatic hydrolysis of L-Arg leads to the formation of ammonium ions which diffuse into the Nafion/PANi layer and induce the electroreduction of PANi at a potential of -0.35 V (vs Ag/AgCl). L-Arg sensitivity is 684 +/- 32 A.M-1.m(-2), and the apparent Michaelis-Menten constant K-M(app)) is 0.31 +/- 0.05 mM. The calibration plot is linear over the range 3-200 mu M L-Arg, the limit of detection is 1 mu M, and the response time (for 90% of the total signal change to occur) is 15 s. The sensor is selective and exhibits good storage stability (amp;gt; 1 month without loss in signal). The biosensor was applied to the analysis of L-Arg in pharmaceutical samples and of ammonium and L-Arg in spiked human plasma obtained from blood of healthy volunteers and those with a hepatic disorder. Data generated were found to be in good agreement with a reference fluorometric enzymatic assay.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
Nyckelord
- L-arginine; Ammonium ions; Amperometry; Nafion; Polyaniline; Recombinant enzyme; Plasma samples; Pharmaceuticals
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas