Sökning: onr:"swepub:oai:DiVA.org:liu-152299" >
Method using in viv...
Method using in vivo quantitative spectroscopy to guide design and optimization of low-cost, compact clinical imaging devices : emulation and evaluation of multispectral imaging systems
-
- Saager, Rolf B., 1974- (författare)
- Beckman Laser Institute and Medical Clinic, Univ. of California, Irvine, USA
-
- Baldado, Melissa L. (författare)
- Beckman Laser Institute and Medical Clinic, Univ. of California, Irvine, USA
-
- Rowland, Rebecca A. (författare)
- Beckman Laser Institute and Medical Clinic, Univ. of California, Irvine, USA
-
visa fler...
-
- Kelly, Kristen M. (författare)
- Beckman Laser Institute and Medical Clinic, USA
-
- Durkin, Anthony J. (författare)
- Beckman Laser Institute and Medical Clinic, USA
-
visa färre...
-
Beckman Laser Institute and Medical Clinic, Univ of California, Irvine, USA Beckman Laser Institute and Medical Clinic, USA (creator_code:org_t)
- SPIE - International Society for Optical Engineering, 2018
- 2018
- Engelska.
-
Ingår i: Journal of Biomedical Optics. - : SPIE - International Society for Optical Engineering. - 1083-3668 .- 1560-2281. ; 23:4
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://www.spiedigi...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- With recent proliferation in compact and/or low-cost clinical multispectral imaging approaches and commercially available components, questions remain whether they adequately capture the requisite spectral content of their applications. We present a method to emulate the spectral range and resolution of a variety of multispectral imagers, based on in-vivo data acquired from spatial frequency domain spectroscopy (SFDS). This approach simulates spectral responses over 400 to 1100 nm. Comparing emulated data with full SFDS spectra of in-vivo tissue affords the opportunity to evaluate whether the sparse spectral content of these imagers can (1) account for all sources of optical contrast present (completeness) and (2) robustly separate and quantify sources of optical contrast (crosstalk). We validate the approach over a range of tissue-simulating phantoms, comparing the SFDS-based emulated spectra against measurements from an independently characterized multispectral imager. Emulated results match the imager across all phantoms (<3 % absorption, <1 % reduced scattering). In-vivo test cases (burn wounds and photoaging) illustrate how SFDS can be used to evaluate different multispectral imagers. This approach provides an in-vivo measurement method to evaluate the performance of multispectral imagers specific to their targeted clinical applications and can assist in the design and optimization of new spectral imaging devices.
Ämnesord
- NATURVETENSKAP -- Fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences (hsv//eng)