SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-174477"
 

Search: onr:"swepub:oai:DiVA.org:liu-174477" > Using Deep Learning...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Using Deep Learning to Emulate the Use of an External Contrast Agent in Cardiovascular 4D Flow MRI

Bustamante, Mariana (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Viola, Federica (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten
Carlhäll, Carljohan (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Fysiologiska kliniken US
show more...
Ebbers, Tino (author)
Linköpings universitet,Avdelningen för diagnostik och specialistmedicin,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
show less...
 (creator_code:org_t)
2021-02-25
2021
English.
In: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 54:3, s. 777-786
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Background Although contrast agents would be beneficial, they are seldom used in four-dimensional (4D) flow magnetic resonance imaging (MRI) due to potential side effects and contraindications. Purpose To develop and evaluate a deep learning architecture to generate high blood-tissue contrast in noncontrast 4D flow MRI by emulating the use of an external contrast agent. Study Type Retrospective. Subjects Of 222 data sets, 141 were used for neural network (NN) training (69 with and 72 without contrast agent). Evaluation was performed on the remaining 81 noncontrast data sets. Field Strength/Sequences Gradient echo or echo-planar 4D flow MRI at 1.5 T and 3 T. Assessment A cyclic generative adversarial NN was trained to perform image translation between noncontrast and contrast data. Evaluation was performed quantitatively using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), structural similarity index (SSIM), mean squared error (MSE) of edges, and Dice coefficient of segmentations. Three observers performed a qualitative assessment of blood-tissue contrast, noise, presence of artifacts, and image structure visualization. Statistical Tests The Wilcoxon rank-sum test evaluated statistical significance. Kendalls concordance coefficient assessed interobserver agreement. Results Contrast in the regions of interest (ROIs) in the NN enhanced images increased by 88%, CNR increased by 63%, and SNR improved by 48% (all P < 0.001). The SSIM was 0.82 +/- 0.01, and the MSE of edges was 0.09 +/- 0.01 (range [0,1]). Segmentations based on the generated images resulted in a Dice similarity increase of 15.25%. The observers managed to differentiate between contrast MR images and our results; however, they preferred the NN enhanced images in 76.7% of cases. This percentage increased to 93.3% for phase-contrast MR angiograms created from the NN enhanced data. Visual grading scores were blood-tissue contrast = 4.30 +/- 0.74, noise = 3.12 +/- 0.98, and presence of artifacts = 3.63 +/- 0.76. Image structures within and without the ROIs resulted in scores of 3.42 +/- 0.59 and 3.07 +/- 0.71, respectively (P < 0.001). Data Conclusion The proposed approach improves blood-tissue contrast in MR images and could be used to improve data quality, visualization, and postprocessing of cardiovascular 4D flow data. Evidence Level 3 Technical Efficacy Stage 1

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Keyword

cardiovascular MRI; 4D flow MRI; contrast enhanced; deep learning; generative adversarial networks

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Bustamante, Mari ...
Viola, Federica
Carlhäll, Carljo ...
Ebbers, Tino
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Image Pr ...
Articles in the publication
Journal of Magne ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view