SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:liu-202347"
 

Search: onr:"swepub:oai:DiVA.org:liu-202347" > Reproducibility of ...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Reproducibility of Laser Doppler Flowmetry in gingival microcirculation. A study on six different protocols

Ajan, Aida (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Käkkliniken US
Roberg, Karin (author)
Linköpings universitet,Avdelningen för cellbiologi,Medicinska fakulteten,Region Östergötland, Öron- näsa- och halskliniken
Fredriksson, Ingemar (author)
Linköpings universitet,Avdelningen för medicinsk teknik,Tekniska fakulteten
show more...
Abtahi, Jahan (author)
Linköpings universitet,Avdelningen för kirurgi, ortopedi och onkologi,Medicinska fakulteten,Region Östergötland, Käkkliniken US
show less...
 (creator_code:org_t)
ACADEMIC PRESS INC ELSEVIER SCIENCE, 2024
2024
English.
In: Microvascular Research. - : ACADEMIC PRESS INC ELSEVIER SCIENCE. - 0026-2862 .- 1095-9319. ; 153
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives: Laser Doppler Flowmetry (LDF) is a non-invasive technique for the assessment of tissue blood flow, but increased reproducibility would facilitate longitudinal studies. The aim of the study was to assess the interday reproducibility of Laser Doppler Flowmetry (LDF) at rest, at elevated local temperatures, and with the use of the vasodilator Methyl Nicotinate (MN) in six interconnected protocols for the measurement of the blood supply to the microvascular bed of the gingiva. Methods: Ten healthy volunteers were included. Interweek LDF measurements with custom-made acrylic splints were performed. Six protocols were applied in separate regions of interest (ROI): 1; basal LDF, 2; LDF with thermoprobe 42 degrees C, 3; LDF with thermoprobe 45 degrees C, 4; LDF with thermoprobe 42 degrees C and MN, 5; LDF with thermoprobe 45 C and MN and 6; LDF with MN. Results: Intra-individual reproducibility was assessed by the within -subject coefficient of variation (wCV) and the intraclass correlation coefficient (ICC). Basal LDF measurements demonstrated high reproducibility with wCV 11.1 in 2 min and 10.3 in 5 min. ICC was 0.9 and 0.92. wCV after heat and MN was 4.9-10.3 and ICC 0.82-0.93. The topically applied MN yielded increased blood flow. Conclusion: This is the first study evaluating the reproducibility of basal LDF compared to single or multiple vasodilatory stimuli in gingiva. Multiple collector fibers probe and stabilizing acrylic splints are recommended. Vasodilatory stimulation showed a tendency toward higher reproducibility. Furthermore, MN yields vasodilation in gingiva.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

Laser Doppler Flowmetry; Microcirculation; Local heating; Thermoprobe; Methyl Nicotinate

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Ajan, Aida
Roberg, Karin
Fredriksson, Ing ...
Abtahi, Jahan
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
Microvascular Re ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view