SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-22150"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-22150" > Myocardial tissue m...

  • Karlsson, M G Daniel,1974-Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan (författare)

Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging

  • Artikel/kapitelEngelska2004

Förlag, utgivningsår, omfång ...

  • Springer,2004
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-22150
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-22150URI
  • https://doi.org/10.1007/BF02345210DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:kth:diva-85847URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • QC 20120228
  • Tissue motion of the beating heart generates large movement artifacts in the laser Doppler perfusion monitoring (LDPM) signal. The aim of the study was to use tissue Doppler imaging (TDI) to localise intervals during the cardiac cycle where the influence of movement artifacts on the LDPM signal is minimum. TDI velocities and LDPM signals were investigated on three calves, for normal heartbeat and during occlusion of the left anterior descending coronary artery. Intervals of low tissue velocity (TDIint<1 cm s−1) during the cardiac cycle were identified. During occlusion, these intervals were compared with low LDPM signal intervals (LDPMint<50% compared with baseline). Low-velocity intervals were found in late systole (normal and occlusion) and late diastole (normal). Systolic intervals were longer and less sensitive to heart rate variation compared with diastolic ones. The overlap between LDPMint and TDIint in relation to TDIint length was 84±27% (n=14). The LDPM signal was significantly (p<0.001, n=14) lower during occlusion if calculated during minimum tissue motion inside TDIint), compared with averaging over the entire cardiac cycle without taking tissue motion into consideration. In conclusion, movement artifacts are reduced if the LDPM signal is correlated to the ECG and investigated during minimum wall motion. The optimum interval depends on the application; late systole and late diastole can be used.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Hübbert, LailaÖstergötlands Läns Landsting,Hjärtcentrum(Swepub:liu)laihu71 (författare)
  • Lönn, UrbanÖstergötlands Läns Landsting,Hjärtcentrum (författare)
  • Janerot-Sjöberg, Birgitta,1958-KTH,Östergötlands Läns Landsting,Hjärtcentrum,Medicinsk teknik(Swepub:kth)u1pw7lam (författare)
  • Ahn, Henrik Casimir,1949-Östergötlands Läns Landsting,Hjärtcentrum(Swepub:liu)henah22 (författare)
  • Wårdell, Karin,1959-Linköpings universitet,Institutionen för medicinsk teknik,Tekniska högskolan,MINT(Swepub:liu)karwa46 (författare)
  • Linköpings universitetInstitutionen för medicinsk teknik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical and Biological Engineering and Computing: Springer42:6, s. 770-7760140-01181741-0444

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy