Sökning: onr:"swepub:oai:DiVA.org:liu-60266" >
Influence of the FI...
Influence of the FID and off-resonance effects in dense MRI
-
- Haraldsson, Henrik, 1977- (författare)
- Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet
-
- Sigfridsson, Andreas (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken
-
- Sakuma, Hajime (författare)
- Department of Radiology, Mie University, Japan
-
visa fler...
-
- Engvall, Jan, 1953- (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US
-
- Ebbers, Tino (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Hälsouniversitetet,Fysiologiska kliniken,Mekanisk värmeteori och strömningslära,Fysiologi,Centrum för medicinsk bildvetenskap och visualisering, CMIV
-
visa färre...
-
(creator_code:org_t)
- 2010-12-02
- 2011
- Engelska.
-
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 65:4, s. 1104-1112
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://onlinelibrar...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Accurate functional measurement in cardiovascular diseases is important as inaccuracy may compromise diagnostic decisions. Cardiac function can be assessed using displacement encoding with stimulated echoes, resulting in three signal components. The free induction decay (FID), arising from spins undergoing T1-relaxation, is not displacement encoded and impairs the displacement acquired. Techniques for suppressing the FID exist; however, a residual will remain. The effect of the residual is difficult to distinguish and investigate in vitro and in vivo. In this work, the influence of the FID as well as of off-resonance effects is evaluated by altering the phase of the FID in relation to the stimulated echo. The results show that the FID and off-resonance effects can impair the accuracy of the displacement measurement acquired. The influence of the FID can be avoided by using an encoded reference. We therefore recommend the assessment of this influence of the FID for each displacement encoding with stimulated echoes protocol.
Nyckelord
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas