Sökning: onr:"swepub:oai:DiVA.org:liu-88167" > Determination of am...
Fältnamn | Indikatorer | Metadata |
---|---|---|
000 | 02475naa a2200313 4500 | |
001 | oai:DiVA.org:liu-88167 | |
003 | SwePub | |
008 | 130130s1984 | |||||||||||000 ||eng| | |
024 | 7 | a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-881672 URI |
024 | 7 | a https://doi.org/10.1016/S0003-2670(00)85624-X2 DOI |
040 | a (SwePub)liu | |
041 | a engb eng | |
042 | 9 SwePub | |
072 | 7 | a ref2 swepub-contenttype |
072 | 7 | a art2 swepub-publicationtype |
100 | 1 | a Winquist, Fredriku Linköpings universitet,Tillämpad Fysik,Tekniska högskolan4 aut0 (Swepub:liu)frewi90 |
245 | 1 0 | a Determination of ammonia in air and aqueous samples with a gas-sensitive semiconductor capacitor |
264 | 1 | b Elsevier,c 1984 |
338 | a print2 rdacarrier | |
520 | a The properties of a new type of ammonia gas-sensitive semiconductor capacitor are described. The sensor is based on a palladium MOS field-effect capacitor with a thin layer (3 nm) of iridium surrounding the palladium gate. The lower limit of detection for ammonia in air is 1 ppm (0.59 mg kg−1). The analytical characteristics and temperature-dependence of the sensor in measurements of ammonia in air are evaluated. Ammonia in aqueous solutions is determined by the use of a continuous flow system utilizing a gaspermeable membrane in combination with the sensor. The calibration plot of the voltage drop of the capacitor vs. ammonia concentration in 150-μl samples is linear in the concentration range 0.2 × 10−6–5 × 10−5 M. Ammonia is determined in rain and river water as well as in whole blood and blood serum; 15 samples per hour can be assayed. Analytical recovery studies and the selectivity properties of the system are described and discussed. Finally, the properties of the flow-through system in continuous monitoring are described. | |
653 | a TECHNOLOGY | |
653 | a TEKNIKVETENSKAP | |
700 | 1 | a Spetz, Anitau Linköpings universitet,Tillämpad Fysik,Tekniska högskolan4 aut0 (Swepub:liu)anill63 |
700 | 1 | a Lundström, Ingemaru Linköpings universitet,Tillämpad Fysik,Tekniska högskolan4 aut0 (Swepub:liu)inglu57 |
700 | 1 | a Danielsson, B.u University of Lund, Sweden4 aut |
710 | 2 | a Linköpings universitetb Tillämpad Fysik4 org |
773 | 0 | t Analytica Chimica Actad : Elsevierg 164, s. 127-138q 164<127-138x 0003-2670x 1873-4324 |
856 | 4 8 | u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-88167 |
856 | 4 8 | u https://doi.org/10.1016/S0003-2670(00)85624-X |
Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.
Kopiera och spara länken för att återkomma till aktuell vy