SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:liu-89641"
 

Sökning: onr:"swepub:oai:DiVA.org:liu-89641" > Synthetic MRI of th...

LIBRIS Formathandbok  (Information om MARC21)
FältnamnIndikatorerMetadata
00005007naa a2200505 4500
001oai:DiVA.org:liu-89641
003SwePub
008130228s2012 | |||||||||||000 ||eng|
009oai:DiVA.org:uu-183798
024a https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-896412 URI
024a https://doi.org/10.1258/ar.2012.1201952 DOI
024a https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-1837982 URI
040 a (SwePub)liud (SwePub)uu
041 a engb eng
042 9 SwePub
072 7a ref2 swepub-contenttype
072 7a art2 swepub-publicationtype
100a Blystad, Idau Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet4 aut0 (Swepub:liu)idabl62
2451 0a Synthetic MRI of the brain in a clinical setting
264 c 2012-12
264 1b Sage Publications,c 2012
338 a electronic2 rdacarrier
520 a BACKGROUND:Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements.PURPOSE:To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images.MATERIAL AND METHODS:Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated.RESULTS:Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images.CONCLUSION:Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study.
650 7a MEDICIN OCH HÄLSOVETENSKAPx Klinisk medicinx Radiologi och bildbehandling0 (SwePub)302082 hsv//swe
650 7a MEDICAL AND HEALTH SCIENCESx Clinical Medicinex Radiology, Nuclear Medicine and Medical Imaging0 (SwePub)302082 hsv//eng
653 a CNS
653 a MR imaging
653 a brain
653 a technology assessment
653 a imaging sequences
653 a MEDICINE
653 a MEDICIN
700a Warntjes, Jan Bertus Marcelu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US4 aut0 (Swepub:liu)marwa64
700a Smedby, Örjanu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiologi,Hälsouniversitetet,Röntgenkliniken i Linköping4 aut0 (Swepub:liu)orjsm14
700a Landtblom, Anne-Marieu Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Neurologi,Hälsouniversitetet,Neurologiska kliniken4 aut0 (Swepub:liu)annla55
700a Lundberg, Peteru Östergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen US4 aut0 (Swepub:liu)petlu11
700a Larsson, Elna-Marieu Uppsala universitet,Enheten för radiologi,Uppsala University, Sweden4 aut0 (Swepub:uu)elnla305
700a Warntjes, Jbm4 aut
710a Linköpings universitetb Centrum för medicinsk bildvetenskap och visualisering, CMIV4 org
773t Acta Radiologicad : Sage Publicationsg 53:10, s. 1158-1163q 53:10<1158-1163x 0284-1851x 1600-0455
856u https://liu.diva-portal.org/smash/get/diva2:608602/FULLTEXT01.pdfx primaryx Raw objecty fulltext:postprint
856u http://liu.diva-portal.org/smash/get/diva2:608602/FULLTEXT01
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-89641
8564 8u https://doi.org/10.1258/ar.2012.120195
8564 8u https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-183798

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy