SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:ltu-101253"
 

Sökning: onr:"swepub:oai:DiVA.org:ltu-101253" > The Validity of a T...

The Validity of a Three-Dimensional Motion Capture System and the Garmin Running Dynamics Pod in Connection with an Assessment of Ground Contact Time While Running in Place

Drobnič, Miha (författare)
Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia
Verdel, Nina (författare)
Mittuniversitetet,Institutionen för hälsovetenskaper (HOV),Department of Health Sciences, Mid Sweden University, 83125 Östersund, Sweden
Holmberg, Hans-Christer (författare)
Luleå tekniska universitet,Hälsa, medicin och rehabilitering,School of Kinesiology, University of British Columbia, Vancouver, BC V6T 1Z4, Canada,Luleå University of Technology; University of British Columbia, Vancouver, Canada
visa fler...
Supej, Matej (författare)
Mittuniversitetet,Institutionen för hälsovetenskaper (HOV),Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia; Department of Health Sciences, Mid Sweden University, 83125 Östersund, Sweden
visa färre...
 (creator_code:org_t)
Multidisciplinary Digital Publishing Institute (MDPI), 2023
2023
Engelska.
Ingår i: Sensors. - : Multidisciplinary Digital Publishing Institute (MDPI). - 1424-8220. ; 23:16
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A three-dimensional motion capture system (MoCap) and the Garmin Running Dynamics Pod can be utilised to monitor a variety of dynamic parameters during running. The present investigation was designed to examine the validity of these two systems for determining ground contact times while running in place by comparing the values obtained with those provided by the bilateral force plate (gold standard). Eleven subjects completed three 20-s runs in place at self-selected rates, starting slowly, continuing at an intermediate pace, and finishing rapidly. The ground contact times obtained with both systems differed significantly from the gold standard at all three rates, as well as for all the rates combined (p < 0.001 in all cases), with the smallest mean bias at the fastest step rate for both (11.5 ± 14.4 ms for MoCap and −81.5 ± 18.4 ms for Garmin). This algorithm was developed for the determination of ground contact times during normal running and was adapted here for the assessment of running in place by the MoCap, which could be one explanation for its lack of validity. In conclusion, the wearables developed for monitoring normal running cannot be assumed to be suitable for determining ground contact times while running in place.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Annan hälsovetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Other Health Sciences (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Idrottsvetenskap (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Sport and Fitness Sciences (hsv//eng)

Nyckelord

3D kinematics
accelerometer
force plate
IMU
inertial sensor
performance
wearables
Physiotherapy
Fysioterapi
Centre - Centre for Sports and Performance Technology (SPORTC)
Centrumbildning - Centrum för idrotts- och prestationsteknologi (SPORTC)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Sensors (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Drobnič, Miha
Verdel, Nina
Holmberg, Hans-C ...
Supej, Matej
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Annan hälsoveten ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Idrottsvetenskap
Artiklar i publikationen
Sensors
Av lärosätet
Luleå tekniska universitet
Mittuniversitetet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy