SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:mau-15741"
 

Sökning: onr:"swepub:oai:DiVA.org:mau-15741" > A novel method for ...

A novel method for superimposition and measurements on maxillary digital 3D models-studies on validity and reliability

Ganzer, Niels (författare)
Uppsala universitet,Centrum för klinisk forskning, Gävleborg,Publ Dent Serv Reg Gavleborg, Dept Orthodont, Box 57, SE-80102 Gavle, Sweden
Feldmann, Ingalill (författare)
Uppsala universitet,Centrum för klinisk forskning, Gävleborg,Publ Dent Serv Reg Gavleborg, Dept Orthodont, Box 57, SE-80102 Gavle, Sweden
Liv, Per (författare)
Uppsala universitet,Centrum för klinisk forskning, Gävleborg
visa fler...
Bondemark, Lars (författare)
Malmö universitet,Odontologiska fakulteten (OD),Malmo Univ, Fac Odontol, Dept Orthodont, SE-20506 Malmo, Sweden.
visa färre...
 (creator_code:org_t)
2017-04-22
2018
Engelska.
Ingår i: European Journal of Orthodontics. - : Oxford University Press. - 0141-5387 .- 1460-2210. ; 40:1, s. 45-51
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Serial 3D models can be used to analyze changes, but correct superimposition is crucial before measurements can be assessed. Earlier studies show that every palatal structure changes due to growth or treatment. Here, we describe a new method that uses an algorithm-based analysis to perform superimpositions and measurements in maxillary 3D models. This method can be used to identify deformations. In a second step, only unchanged areas are used for superimposition. Objectives: This study investigates the validity and reliability of this novel method. Methods: Digital 3D models from 16 cases were modified by an independent 3D engineer to simulate space closure and growth. True values for tooth movements were available as reference. Measurements and repeated measurements were performed by four observers. Results: The total tooth movement had an absolute mean error of 0.0225 mm (SD 0.03). The intraclass correlation coefficient (ICC) was 0.9996. Rotational measurements had an absolute mean error of 0.0291 degrees (SD 0.04 degrees) and an ICC of 0.9999. Limitations: Serial models need to be taken with a moderate interval (1 to 2 years). Obvious changed areas in the palate need to be cropped before processing the models. Conclusion: The tested method is valid and reliable with excellent accuracy and precision even when changes through growth or orthodontic treatment occur.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

maxilla
palate
tooth movement
precision
Orthodontics
3D
Superimposition
Validity and Reliability
Measure tooth movement

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ganzer, Niels
Feldmann, Ingali ...
Liv, Per
Bondemark, Lars
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
European Journal ...
Av lärosätet
Malmö universitet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy