Lund University,Lunds universitet,Metalund,Annan verksamhet, LTH,Lunds Tekniska Högskola,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Ergonomi och aerosolteknologi,Institutionen för designvetenskaper,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Other operations, LTH,Faculty of Engineering, LTH,Ergonomics and Aerosol Technology,Department of Design Sciences,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2020-10-25
2020
Engelska.
Ingår i: Atmosphere. - : MDPI AG. - 2073-4433. ; 11:11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Indoor combustion processes associated with cooking, heating, and smoking are a major source of aerosols in Jordanian dwellings. To evaluate human exposure to combustion-generated aerosols in Jordanian indoor environments, regional inhaled deposited dose rates of indoor aerosols (10 nm to 25 µm) were determined for different scenarios for adult occupants. The inhaled deposited dose rate provides an estimate of the number or mass of inhaled aerosol that deposits in each region of the respiratory system per unit time. In general, sub-micron particle number (PN1) dose rates ranged from 109 to 1012 particles/h, fine particle mass (PM2.5) dose rates ranged from 3 to 216 µg/h, and coarse particle mass (PM10) dose rates ranged from 30 to 1600 µg/h. Dose rates were found to be dependent on the type and intensity of indoor combustion processes documented in the home. Dose rates were highest during cooking activities using a natural gas stove, heating via natural gas and kerosene, and smoking (shisha/tobacco). The relative fraction of the total dose rate received in the head airways, tracheobronchial, and alveolar regions varied among the documented indoor combustion (and non-combustion) activities. The significant fraction of sub-100 nm particles produced during the indoor combustion processes resulted in high particle number dose rates for the alveolar region. Suggested approaches for reducing indoor aerosol dose rates in Jordanian dwellings include a reduction in the prevalence of indoor combustion sources, use of extraction hoods to remove combustion products, and improved ventilation/filtration in residential buildings.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)
NATURVETENSKAP  -- Geovetenskap och miljövetenskap (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences (hsv//eng)

Nyckelord

Aerosol dose rate
Human exposure
Indoor air quality
Lung deposition
Particle number size distributions
Particulate matter (PM)
Ultrafine particles

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hussein, Tareq
Boor, Brandon E.
Löndahl, Jakob
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Arbetsmedicin oc ...
NATURVETENSKAP
NATURVETENSKAP
och Geovetenskap och ...
Artiklar i publikationen
Atmosphere
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy