SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:ri-12329"
 

Search: onr:"swepub:oai:DiVA.org:ri-12329" > Behaviour of an int...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Behaviour of an intumescing system subjected to different heating conditions

Johansson, Nils (author)
Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH,Lund University, Sweden
Van Hees, Patrick (author)
Lund University,Lunds universitet,Avdelningen för Brandteknik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Fire Safety Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH,Lund University, Sweden
Jansson, Robert (author)
RISE,Brandmotstånd
show more...
Sjöström, Johan (author)
RISE,Brandmotstånd
Grayson, Stephen (editor)
show less...
 (creator_code:org_t)
2013
2013
English.
In: Fire and Materials 2013 - 13th International Conference and Exhibition, Conference Proceedings. ; , s. 187-196
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Previous studies have indicated that the expansion of fire seals and fire stoppers will be dependent on the heat exposure. Standardized methods for classification includes exposure to a rapid heat exposure of the product that is tested, but this might not always be the worst case scenario for the product. In this paper a series of tests are presented in order to study how a graphite based intumescing system, intended for cavities, reacts when subjected to fire conditions different form that in the standardised method EN 1366-4. Two different experimental setups, a cone calorimeter at Lund University and a small-scale furnace at SP Fire Technology, were used in the tests. The start of expansion reaction in the tested fire stopper was around 180°C. The start of reaction temperature is rather independent of the incident heat flux, while expansion rate is clearly dependent on the incident heat flux. Furthermore, the studied fire stopper performed well in the small-scale furnace because the graphite expanded enough to give the same protection, although it is preheated or wet, as when subjected to a heat exposure similar to ISO 834. These results are good but they are only considered valid for the studied system and for the given situation. Future research is needed in order to study how other types of intumescing fire protection systems work when subjected to realistic fire environments.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Annan samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Other Civil Engineering (hsv//eng)

Keyword

Exhibitions
Fires
Graphite
Heat flux

Publication and Content Type

ref (subject category)
kon (subject category)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Johansson, Nils
Van Hees, Patric ...
Jansson, Robert
Sjöström, Johan
Grayson, Stephen
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Building Technol ...
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Other Civil Engi ...
Articles in the publication
By the university
RISE
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view