Sökning: onr:"swepub:oai:DiVA.org:ri-6577" >
Dynamic whole syste...
Dynamic whole system testing of combined renewable heating systems : The current state of the art
-
- Haller, Michel Y. (författare)
- Hochschule für Technik (HSR), Switzerland,SPF Institut für Solartechnik, Hochschule für Technik
-
- Haberl, Robert (författare)
- Hochschule für Technik (HSR), Switzerland,SPF Institut für Solartechnik, Hochschule für Technik
-
- Persson, Tomas, 1972- (författare)
- Högskolan Dalarna,Energi och miljöteknik
-
visa fler...
-
- Bales, Chris (författare)
- Högskolan Dalarna,Energi och miljöteknik
-
- Kovacs, Peter (författare)
- RISE,Klimatisering och installationsteknik,Technical Research Institutue of Sweden
-
- Cheze, David (författare)
- CEA LITEN, France,CEA, INES
-
- Papillon, Philippe (författare)
- CEA LITEN, France,CEA, INES
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2013
- 2013
- Engelska.
-
Ingår i: Energy and Buildings. - : Elsevier BV. - 0378-7788 .- 1872-6178. ; 66:Nov, s. 667-677
- Relaterad länk:
-
http://du.diva-porta...
-
visa fler...
-
https://du.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective For the evaluation of the energetic performance of combined renewable heating systems that supply space heat and domestic hot water for single family houses, dynamic behaviour, component interactions, and control of the system play a crucial role and should be included in test methods. Methods New dynamic whole system test methods were developed based on "hardware in the loop" concepts. Three similar approaches are described and their differences are discussed. The methods were applied for testing solar thermal systems in combination with fossil fuel boilers (heating oil and natural gas), biomass boilers, and/or heat pumps. Results All three methods were able to show the performance of combined heating systems under transient operating conditions. The methods often detected unexpected behaviour of the tested system that cannot be detected based on steady state performance tests that are usually applied to single components. Conclusion Further work will be needed to harmonize the different test methods in order to reach comparable results between the different laboratories. Practice implications A harmonized approach for whole system tests may lead to new test standards and improve the accuracy of performance prediction as well as reduce the need for field tests.
Nyckelord
- Dynamic testing
- Emulation
- Energy labelling
- Hardware in the loop
- Heat pump
- Renewable heating
- Simulation
- Solar thermal
- Whole system testing
- MacSheep
Publikations- och innehållstyp
- ref (ämneskategori)