Evaluation of microextraction by packed sorbent and micro-liquid chromatography-tandem mass spectrometry as a green approach in bioanalysis

Abdel-Rehim, Abbi (författare)
Stockholms universitet,Institutionen för analytisk kemi
Abdel-Rehim, Mohamed (författare)
Stockholms universitet,Institutionen för analytisk kemi
 (creator_code:org_t)
2012-11-21
2013
Engelska.
Ingår i: BMC Biomedical chromotography. - : Wiley. - 0269-3879 .- 1099-0801. ; 27:10, s. 1225-1233
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this study the use of micro-liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) was investigated in routine bioanalysis application for separation and quantification of pro-drug AZD6319 (developed for aldezheimer treatment). Microextraction by packed sorbent (MEPS) was used as sample clean-up method. The focus of this study was put on the evaluation of the usability of smaller column diameters such as 1.0 and 0.3mm instead of 2.1mm in bioanalysis application to reduce solvent consumption and sample volumes. Solvent consumption was reduced by 80% when a 1.0mm column was used compared with 2.1mm column. Robustness of the micro-columns in terms of accuracy and precision was investigated. The application of LC-MS/MS for the quantitative analysis of AZD6319 in plasma samples showed good selectivity, accuracy and precision. The coefficients of determination (R-2) were >0.998 for all runs using plasma samples on the studied micro-columns. The inter-day accuracy values for quality control samples ranged from 99 to 103% and from 96 to 105% for 0.3x50mm and 1.0x50mm columns, respectively. The inter-day precision values ranged from 4.0 to 9.0% and from 4.0 to 8.0% for 0.3x50 and 1.0x50mm columns, respectively. In addition the sensitivity was increased by three times using a 1.0mm column compared with 2.1mm. Furthermore, robustness of the micro-columns from different manufacturers was investigated.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)
NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

microextraction by packed sorbent
micro-LC columns
plasma samples
green bioanalysis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abdel-Rehim, Abb ...
Abdel-Rehim, Moh ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Biologi
och Biokemi och mole ...
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
BMC Biomedical c ...
Av lärosätet
Stockholms universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy