Sökning: onr:"swepub:oai:DiVA.org:umu-151791" >
Polysulfide/Graphen...
Polysulfide/Graphene Nanocomposite Film for Simultaneous Electrochemical Determination of Cadmium and Lead Ions
-
Jiang, Ruyuan (författare)
-
Liu, Niantao (författare)
-
Su, Yuhong (författare)
-
visa fler...
-
Gao, Sanshuang (författare)
-
Mamat, Xamxikamar (författare)
-
- Wågberg, Thomas, 1971- (författare)
- Umeå universitet,Institutionen för fysik
-
Li, Yongtao (författare)
-
Hu, Xun (författare)
-
- Hu, Guangzhi (författare)
- Umeå universitet,Institutionen för fysik,Chinese Acad Sci, Xinjiang Tech Inst Phys & Chem, State Key Lab Basis Xinjiang Indigenous Med Plant, Key Lab Chem Plant Resources Arid Reg, Urumqi 830011, Peoples R China
-
visa färre...
-
(creator_code:org_t)
- World Scientific, 2018
- 2018
- Engelska.
-
Ingår i: NANO. - : World Scientific. - 1793-2920 .- 1793-7094. ; 13:8
- Relaterad länk:
-
https://urn.kb.se/re...
-
visa fler...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- An integrative electroanalytical method was developed for detecting Cd2+ and Pb2+ ions in aqueous solutions. Polysulfide/graphene (RGO-S) nanocomposites were prepared and their performance as electrochemical sensors for Cd2+ and Pb2+ was evaluated. The RGO-S nanocomposite was carefully characterized by scanning electron microscopy with energy-dispersive X-ray spectrometry, transmission electron microscopy, and X-ray photoelectron spectroscopy. The as-prepared RGO-S was incorporated into a pyrolytic graphite electrode (RGO-S/PGE) and used for detecting trace amount of Cd2+ and Pb2+ by differential pulse anodic stripping voltammetry. Under optimal conditions, the stripping peak current of RGO-S/PGE varies linearly with heavy metal ion concentration in the ranges 2.0-300 mu g L-1 for Cd2+ and 1.0-300 mu g L-1 for Pb2+. The limits of detection for Cd2+ and Pb2+ were estimated to be about 0.67 mu g L-1 and 0.17 mu g L-1, respectively. The prepared electrochemical heavy-metal-detecting electrode provides good repeatability and reproducibility with high sensitivity, making it a suitable candidate for monitoring Cd2+ and Pb2+ concentrations in aqueous environmental samples.
Ämnesord
- NATURVETENSKAP -- Kemi -- Materialkemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Materials Chemistry (hsv//eng)
- NATURVETENSKAP -- Fysik -- Den kondenserade materiens fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Condensed Matter Physics (hsv//eng)
Nyckelord
- Graphene
- polysulfide
- Cd2
- Pb2
- simultaneous determination
- sensor
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
-
NANO
(Sök värdpublikationen i LIBRIS)
Till lärosätets databas
- Av författaren/redakt...
-
Jiang, Ruyuan
-
Liu, Niantao
-
Su, Yuhong
-
Gao, Sanshuang
-
Mamat, Xamxikama ...
-
Wågberg, Thomas, ...
-
visa fler...
-
Li, Yongtao
-
Hu, Xun
-
Hu, Guangzhi
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Kemi
-
och Materialkemi
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
-
och Den kondenserade ...
- Artiklar i publikationen
-
NANO
- Av lärosätet
-
Umeå universitet