Determination of C-21 ketosteroids in serum using trifluoromethanesulfonic acid catalyzed precolumn dansylation and 1,1’-oxalyldiimidazole postcolumn peroxyoxalate chemiluminescence detection

Appelblad, Patrik (author)
Umeå universitet,Institutionen för klinisk vetenskap,Kemiska institutionen
Jonsson, Tobias (author)
Umeå universitet,Kemiska institutionen
Bäckström, Torbjörn (author)
Umeå universitet,Obstetrik och gynekologi
show more...
Irgum, Knut (author)
Umeå universitet,Kemiska institutionen
show less...
 (creator_code:org_t)
1998-10-24
1998
English.
In: Analytical Chemistry. - Washington : American Chemical Society (ACS). - 0003-2700 .- 1520-6882. ; 70:23, s. 5002-5009
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • A new procedure for the quantitation of C-21 ketosteroids using trifluoromethanesulfonic acid-catalyzed precolumn dansylation and coupled column liquid chromatographic separation, followed by postcolumn 1,1‘-oxalyldiimidazole peroxyoxalate chemiluminescence detection is presented. In the simultaneous optimization of chromatographic resolution and chemiluminescence intensity, a coupled column chromatographic system and a stopped-flow system were used. An eluent containing 20 mM phosphate buffer at pH 6.7 accomplished an efficient separation of 3α-hydroxy-5β-pregnan-20-one from a mixture containing 10 C-21 ketosteroids. Phosphate buffer also proved to be the most advantageous, among the six buffers tested, for sensitive detection. Experimental design and multivariate data analysis were used to characterize and optimize the postcolumn reaction chemistry in the chromatographic system. A valid full factorial design with excellent predictability showed that the flow rates for both 1,1‘-oxalyldiimidazole and hydrogen peroxide were the factors most strongly affecting the sensitivity of the system. The theoretical plate numbers were above 11 000 for all 10 dansylated ketosteroids. The 3σ detection limit estimated from 3α-hydroxy-5β-pregnan-20-one calibration curve data was 1.6 pmol (n = 4, 125 μL injected) and spiked serum containing 0−74 pmol of this compound showed overall recoveries of 73 ± 9% (n = 12). Quantitation of 3α-hydroxy-5β-pregnan-20-one was finally carried out on 45 serum samples and the results compared to those from a radioimmunoassay (RIA) method. The data acquired with the procedure described in this work compare well with the results from RIA, which confirms the reliability of the new analytical procedure.

Subject headings

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Keyword

performance liquid chromatography
bile-acids
steroids
reagent
system

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Appelblad, Patri ...
Jonsson, Tobias
Bäckström, Torbj ...
Irgum, Knut
About the subject
NATURAL SCIENCES
NATURAL SCIENCES
and Chemical Science ...
and Analytical Chemi ...
Articles in the publication
Analytical Chemi ...
By the university
Umeå University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view