SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:umu-57255"
 

Search: onr:"swepub:oai:DiVA.org:umu-57255" > Assessment of abdom...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Assessment of abdominal muscle function using the Biodex System-4. Validity and reliability in healthy volunteers and patients with giant ventral hernia

Gunnarsson, Ulf, 1967- (author)
Karolinska Institutet
Johansson, M (author)
Department of Physiotherapy, Karolinska Institutet, Karolinska University Hospital, Huddinge, Stockholm, Sweden
Strigård, Karin, 1958- (author)
Karolinska Institutet
 (creator_code:org_t)
2011-03-05
2011
English.
In: Hernia. - Paris : Springer. - 1265-4906 .- 1248-9204. ; 15:4, s. 417-421
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: The decrease in recurrence rates in ventral hernia surgery have led to a redirection of focus towards other important patient-related endpoints. One such endpoint is abdominal wall function. The aim of the present study was to evaluate the reliability and external validity of abdominal wall strength measurement using the Biodex System-4 with a back abdomen unit.MATERIAL AND METHOD: Ten healthy volunteers and ten patients with ventral hernias exceeding 10 cm were recruited. Test-retest reliability, both with and without girdle, was evaluated by comparison of measurements at two test occasions 1 week apart. Reliability was calculated by the interclass correlation coefficients (ICC) method. Validity was evaluated by correlation with the well-established International Physical Activity Questionnaire (IPAQ) and a self-assessment of abdominal wall strength.RESULTS: One person in the healthy group was excluded after the first test due to neck problems following minor trauma. The reliability was excellent (>0.75), with ICC values between 0.92 and 0.97 for the different modalities tested. No differences were seen between testing with and without a girdle. Validity was also excellent both when calculated as correlation to self-assessment of abdominal wall strength, and to IPAQ, giving Kendall tau values of 0.51 and 0.47, respectively, and corresponding P values of 0.002 and 0.004.CONCLUSION: Measurement of abdominal muscle function using the Biodex System-4 is a reliable and valid method to assess this important patient-related endpoint. Further investigations will be made to explore the potential of this technique in the evaluation of the results of ventral hernia surgery, and to compare muscle function after different abdominal wall reconstruction techniques.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Keyword

Giant ventral hernia
Abdominal muscle strength
Biodex System-4
Girdle

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

  • Hernia (Search for host publication in LIBRIS)

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Gunnarsson, Ulf, ...
Johansson, M
Strigård, Karin, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Surgery
Articles in the publication
Hernia
By the university
Umeå University
Karolinska Institutet

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view