Sökning: onr:"swepub:oai:DiVA.org:uu-274709" >
A study of the pres...
A study of the pressure profiles near the first pumping aperture in a high pressure photoelectron spectrometer
-
- Kahk, J. Matthias (författare)
- Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2AZ, England.
-
- Villar-Garcia, Ignacio J. (författare)
- Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2AZ, England.
-
- Grechy, Lorenza (författare)
- Univ London Imperial Coll Sci Technol & Med, Dept Aeronaut, London SW7 2AZ, England.
-
visa fler...
-
- Bruce, Paul J. K. (författare)
- Univ London Imperial Coll Sci Technol & Med, Dept Aeronaut, London SW7 2AZ, England.
-
- Vincent, Peter E. (författare)
- Univ London Imperial Coll Sci Technol & Med, Dept Aeronaut, London SW7 2AZ, England.
-
- Eriksson, Susanna K. (författare)
- Uppsala universitet,Institutionen för kemi - Ångström
-
- Rensmo, Håkan (författare)
- Uppsala universitet,Molekyl- och kondenserade materiens fysik
-
- Hahlin, Maria (författare)
- Uppsala universitet,Molekyl- och kondenserade materiens fysik
-
- Ahlund, John (författare)
- VG Scienta AB, S-75015 Uppsala, Sweden.
-
- Edwards, Marten O. M. (författare)
- VG Scienta AB, S-75015 Uppsala, Sweden.
-
- Payne, David J. (författare)
- Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2AZ, England.
-
visa färre...
-
Univ London Imperial Coll Sci Technol & Med, Dept Mat, London SW7 2AZ, England Univ London Imperial Coll Sci Technol & Med, Dept Aeronaut, London SW7 2AZ, England. (creator_code:org_t)
- Elsevier BV, 2015
- 2015
- Engelska.
-
Ingår i: Journal of Electron Spectroscopy and Related Phenomena. - : Elsevier BV. - 0368-2048 .- 1873-2526. ; 205, s. 57-65
- Relaterad länk:
-
http://spiral.imperi...
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In a high-pressure photoelectron spectrometer, the sample is positioned close to a differential pumping aperture, behind which the pressure is several orders of magnitude lower than the pressure in the analysis chamber. To find the optimal sample position, where the path length of the photoelectrons through the high pressure region is minimized as far as possible without compromising knowledge of the actual pressure at the sample surface, an understanding of the pressure variations near the sample and the aperture is required. A computational fluid dynamics study has been carried out to examine the pressure profiles, and the results are compared against experimental spectra whose intensities are analyzed using the Beer-Lambert law. The resultant pressure profiles are broadly similar to the one previously derived from a simplistic molecular flow model, but indicate that as the pressure in the analysis chamber is raised, the region over which the pressure drop occurs becomes progressively narrower.
Ämnesord
- NATURVETENSKAP -- Fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences (hsv//eng)
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Kahk, J. Matthia ...
-
Villar-Garcia, I ...
-
Grechy, Lorenza
-
Bruce, Paul J. K ...
-
Vincent, Peter E ...
-
Eriksson, Susann ...
-
visa fler...
-
Rensmo, Håkan
-
Hahlin, Maria
-
Ahlund, John
-
Edwards, Marten ...
-
Payne, David J.
-
visa färre...
- Om ämnet
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
- Artiklar i publikationen
-
Journal of Elect ...
- Av lärosätet
-
Uppsala universitet