Population Pharmacokinetics of Plasma-Derived Factor IX : Procedures for Dose Individualization

Brekkan, Ari (författare)
Uppsala University,Uppsala universitet,Institutionen för farmaceutisk biovetenskap
Berntorp, Erik (författare)
Lund University,Lunds universitet,Klinisk koagulationsmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Coagulation, Malmö,Lund University Research Groups,Skane Univ Hosp, Clin Coagulat Res Unit, Malmo, Sweden
Jensen, Kirsten (författare)
Skane Univ Hosp, Clin Coagulat Res Unit, Malmo, Sweden
visa fler...
Nielsen, Elisabet I (författare)
Uppsala University,Uppsala universitet,Institutionen för farmaceutisk biovetenskap,Farmakometri
Jönsson, Siv (författare)
Uppsala University,Uppsala universitet,Institutionen för farmaceutisk biovetenskap
visa färre...
 (creator_code:org_t)
Elsevier BV, 2016
2016
Engelska.
Ingår i: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 14:4, s. 724-732
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Population pharmacokinetic (POPPK) models describing factor IX (FIX) activity levels in plasma, in combination with individual FIX measurements, may be used to individualize dosing in the treatment of hemophilia B. Objectives: The aim was to reevaluate a previously developed POPPK model for FIX activity and to explore the number and timing of FIX samples required in pharmacokinetic (PK) dose individualization. Methods: The POPPK model was reevaluated using an extended data set. Several sampling schedules, varying with respect to the timing and number of samples, were evaluated in a simulation study with relative dose errors compared between schedules. The performance of individually calculated doses was compared with commonly prescribed FIX doses with respect to the number of patients with a trough FIX activity > 0.01 U mL(-1). Results and conclusions: A three-compartment PK model best described the FIX activity levels. The number and timing of samples greatly influenced imprecision in dose prediction. Schedules with single samples taken on both day 2 and day 3 were identified as being convenient schedules with an acceptable performance level. Individually calculated doses performed better with respect to patient target attainment than a fixed 40 U kg(-1) dose regardless of how many samples were available to calculate individual doses. The results of this study suggest that PK dose tailoring with limited sampling may be applicable for plasma-derived FIX products.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Hematologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Hematology (hsv//eng)

Nyckelord

Bayesian forecast; coagulation factor IX; hemophilia; patient-specific modeling; pharmacokinetics
Farmakokinetik och läkemedelsterapi
Pharmacokinetics and Drug Therapy

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy