SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:uu-439545"
 

Search: onr:"swepub:oai:DiVA.org:uu-439545" > Left ventricular vo...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Nordström, JonnyUppsala universitet,Centrum för klinisk forskning, Gävleborg,Radiologi (author)

Left ventricular volumes and ejection fraction from cardiac ECG-gated 15O-water positron emission tomography compared to cardiac magnetic resonance imaging using simultaneous hybrid PET/MR

  • Article/chapterEnglish2023

Publisher, publication year, extent ...

  • 2022-12-08
  • Springer Nature,2023
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:uu-439545
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-439545URI
  • https://doi.org/10.1007/s12350-022-03154-7DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • Background15O-water PET is the gold standard for noninvasive quantification of myocardial blood flow. In addition to evaluation of ischemia, the assessment of cardiac function and remodeling is important in all cardiac diseases. However, since 15O-water is freely diffusible and standard uptake images show little contrast between the myocardium and blood pool, the assessment of left-ventricular (LV) volumes and ejection fraction (EF) is challenging. Therefore, the aim of the present study was to investigate the feasibility of calculating LV volumes and EF from first-pass analysis of 15O-water PET, by comparison with cardiac magnetic resonance imaging (CMR) using a hybrid PET/MR scanner.MethodsTwenty-four patients with known or suspected CAD underwent a simultaneous ECG-gated cardiac PET/MR scan. The 15O-water first-pass images (0-50 seconds) were analyzed using the CarPET software and the CMR images were analyzed using the software Segment, for LV volumes and EF calculations. The LV volumes and EF were compared using correlation and Bland–Altman analysis. In addition, inter- and intra-observer variability of LV volumes and EF were assessed for both modalities.ResultsThe correlation between PET and CMR was strong for volumes (r > 0.84) and moderate for EF (r = 0.52), where the moderate correlation for EF was partly due to the small range of EF values. Agreement was high for all parameters, with a slight overestimation of PET values for end-diastolic volume but with no significant mean bias for other parameters. Inter- and intra-observer agreement of volumes was high and comparable between PET and CMR. For EF, inter-observer agreement was higher for PET and intra-observer agreement was higher for CMR.ConclusionLV volumes and EF can be calculated by first-pass analysis of a 15O-water PET scan with high accuracy and comparable precision as with CMR.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Kvernby, SofiaUppsala universitet,Radiologi,Medical Physics, Uppsala University Hospital, Uppsala, Sweden(Swepub:uu)sofkv986 (author)
  • Kero, TanjaUppsala universitet,Radiologi,Medical Physics, Uppsala University Hospital, Uppsala, Sweden(Swepub:uu)tanke311 (author)
  • Sörensen, JensUppsala universitet,Radiologi,Medical Imaging Centre, Uppsala University Hospital, Uppsala, Sweden(Swepub:uu)jenssore (author)
  • Harms, Hendrik J.Uppsala universitet,Radiologi(Swepub:uu)henha488 (author)
  • Lubberink, MarkUppsala universitet,Radiologi,Medical Physics, Uppsala University Hospital, Uppsala, Sweden(Swepub:uu)marklubb (author)
  • Uppsala universitetCentrum för klinisk forskning, Gävleborg (creator_code:org_t)

Related titles

  • In:Journal of Nuclear Cardiology: Springer Nature30:4, s. 1352-13621071-35811532-6551

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view