Sökning: onr:"swepub:oai:DiVA.org:uu-506413" >
Transmission-Based ...
Transmission-Based Vertebrae Strength Probe Development : Far Field Probe Property Extraction and Integrated Machine Vision Distance Validation Experiments
-
- Meaney, Paul (författare)
- Uppsala universitet,Institutionen för elektroteknik,Dartmouth Coll, Thayer Sch Engn, Hanover, NH 03755 USA.
-
- Augustine, Robin, 1982- (författare)
- Uppsala universitet,Fasta tillståndets elektronik
-
- Welteke, Adrian (författare)
- Helmut Schmidt Univ, Elect Engn Dept, D-22043 Hamburg, Germany.
-
visa fler...
-
Pfrommer, Bernd (författare)
-
- Pearson, Adam M. (författare)
- Dartmouth Coll, Geisel Sch Med, Lebanon, NH 03766 USA.
-
- Brisby, Helena (författare)
- Sahlgrenska Hosp, Orthoped Dept, S-41345 Gothenburg, Sweden.
-
visa färre...
-
(creator_code:org_t)
- MDPI AG, 2023
- 2023
- Engelska.
-
Ingår i: Sensors. - : MDPI AG. - 1424-8220. ; 23:10
- Relaterad länk:
-
https://doi.org/10.3...
-
visa fler...
-
https://uu.diva-port... (primary) (Raw object)
-
https://urn.kb.se/re...
-
https://doi.org/10.3...
-
visa färre...
Abstract
Ämnesord
Stäng
- We are developing a transmission-based probe for point-of-care assessment of vertebrae strength needed for fabricating the instrumentation used in supporting the spinal column during spinal fusion surgery. The device is based on a transmission probe whereby thin coaxial probes are inserted into the small canals through the pedicles and into the vertebrae, and a broad band signal is transmitted from one probe to the other across the bone tissue. Simultaneously, a machine vision scheme has been developed to measure the separation distance between the probe tips while they are inserted into the vertebrae. The latter technique includes a small camera mounted to the handle of one probe and associated fiducials printed on the other. Machine vision techniques make it possible to track the location of the fiducial-based probe tip and compare it to the fixed coordinate location of the camera-based probe tip. The combination of the two methods allows for straightforward calculation of tissue characteristics by exploiting the antenna far field approximation. Validation tests of the two concepts are presented as a precursor to clinical prototype development.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
Nyckelord
- vertebrae
- instrumentation
- osteoporosis
- microwave
- transmission
- machine vision
- surgical navigation