SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-524458"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-524458" > Early prediction of...

  • Persson, IngerUppsala universitet,Statistiska institutionen (författare)

Early prediction of sepsis in intensive care patients using the machine learning algorithm NAVOY® Sepsis, a prospective randomized clinical validation study

  • Artikel/kapitelEngelska2024

Förlag, utgivningsår, omfång ...

  • Elsevier,2024
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:uu-524458
  • https://urn.kb.se/resolve?urn=urn:nbn:se:uu:diva-524458URI
  • https://doi.org/10.1016/j.jcrc.2023.154400DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Purpose:To prospectively validate, in an ICU setting, the prognostic accuracy of the sepsis prediction algorithm NAVOY® Sepsis which uses 4 h of input for routinely collected vital parameters, blood gas values, and lab values.Materials and methods:Patients 18 years or older admitted to the ICU at Skåne University Hospital Malmö from December 2020 to September 2021 were recruited in the study. A total of 304 patients were randomized into one of two groups: Algorithm group with active sepsis alerts, or Standard of care. NAVOY® Sepsis made silent predictions in the Standard of care group, in order to evaluate its performance without disturbing the outcome. The study was blinded, i.e., study personnel did not know to which group patients were randomized. The healthcare provider followed standard practices in assessing possible development of sepsis and intervening accordingly. The patients were followed-up in the study until ICU discharge. Results:NAVOY® Sepsis could predict the development of sepsis, according to the Sepsis-3 criteria, three hours before sepsis onset with high performance: accuracy 0.79; sensitivity 0.80; and specificity 0.78.Conclusions:The accuracy, sensitivity, and specificity were all high, validating the prognostic accuracy of NAVOY® Sepsis in an ICU setting, including Covid-19 patients.   

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Macura, AndreasAlgoDx AB, Stockholm, Sweden (författare)
  • Becedas, DavidAlgoDx AB, Stockholm, Sweden (författare)
  • Sjövall, FredrikDepartment of Intensive- and Perioperative Medicine, Skåne University Hospital, Malmö, Sweden (författare)
  • Uppsala universitetStatistiska institutionen (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of critical care: Elsevier800883-94411557-8615

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Persson, Inger
Macura, Andreas
Becedas, David
Sjövall, Fredrik
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Anestesi och int ...
Artiklar i publikationen
Journal of criti ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy