SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:DiVA.org:uu-94387"
 

Sökning: onr:"swepub:oai:DiVA.org:uu-94387" > Heparin coating dur...

Heparin coating durability on artificial heart valves studied by XPS and antithrombin binding capacity

Kristensen, Emma (författare)
Uppsala universitet,Fysiska institutionen
Larsson, Rolf (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi
Sánchez, Javier (författare)
Uppsala universitet,Enheten för klinisk immunologi,Biomaterialforskning
visa fler...
Rensmo, Håkan (författare)
Uppsala universitet,Institutionen för fysik och materialvetenskap
Gelius, Ulrik (författare)
Uppsala universitet,Institutionen för fysik och materialvetenskap
Siegbahn, Hans (författare)
Uppsala universitet,Institutionen för fysik och materialvetenskap
visa färre...
 (creator_code:org_t)
Elsevier BV, 2006
2006
Engelska.
Ingår i: Colloids and Surfaces B. - : Elsevier BV. - 0927-7765 .- 1873-4367. ; 49:1, s. 1-7
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The durability and functionality of a heparin coating on artificial heart valve leaflets were evaluated with X-ray photoelectron spectroscopy (XPS) and by the coatings’ capacity to bind antithrombin. Current methods for accelerated life-time testing are based on exposing leaflets to water solutions. In this paper a method is explored, in which heart valve leaflets were exposed to a continuous high shear rate (4 L/min) of human citrated plasma. It was found that the heparin coating was stable and wear resistant enough to still be present after 3 weeks and to have about the same antithrombin uptake as coatings not exposed to circulating plasma. It was, however, partly destroyed by the test as found using XPS. We suggest that heparin chains from the upper layer of heparin have been torn off from the carrier chain, in combination with loss of heparin conjugate and plasma deposition in patches. This study showed that XPS provides additional information to biological measurements such as antithrombin uptake. XPS is therefore a valuable technique not only to characterize biomaterials but also to evaluate the effect of a performance test.

Ämnesord

NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Antithrombins/*chemistry/*metabolism
Biocompatible Materials/*chemistry
Carbohydrate Conformation
Carbohydrate Sequence
Electrons
Heart Valves/*chemistry/*metabolism
Heparin/*chemistry
Humans
Materials Testing
Molecular Sequence Data
Sensitivity and Specificity
Spectrum Analysis
Surface Properties
X-Rays
Chemistry
Kemi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy