SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/152964"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/152964" > Microdosimetric mod...

Microdosimetric modeling of thyroid follicles for At-211

Josefsson, Anders, 1971 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
Forssell-Aronsson, Eva, 1961 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics
 (creator_code:org_t)
2011
2011
Engelska.
Ingår i: European Journal of Nuclear Medicine & Molecular Imaging. - 1619-7070. ; 38:Supplement 2
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • At-211 is more frequently proposed for and used in targeted radionuclide tumour therapy, and is partly taken up by the thyroid gland in a similar way as iodine. For radiation protection purposes it is thus important to have appropriate dosimetric models of At-211 in the thyroid, both for dosimetric evaluation for patients receiving At-211 labelled pharmaceuticals, where the compound in vivo may release some At-211, and for the personnel handling At-211. The aims of this study were to describe a thyroid model for mice, rats and humans and to perform dosimetric calculations for At-211 to study the effect of geometry and biodistribution on absorbed dose/microdosimetric parameters.Material and MethodsSimulations were performed using the general purpose Monte Carlo code MCNPX 2.6.0. The decay of At-211 was simulated taking only the alpha particle emissions into consideration. A thyroid follicle was built up using spherical geometry. The follicle lumen was assumed to be a sphere with the diameter ranging between 10 and 500 micrometer, surrounded by a single layer of follicle cells with 4, 6 or 8 micrometer (diameter) spherical nuclei. Follicle models were created for mouse, rat and human, and for each geometric setup a number of 10.000.000 histories were simulated. The target was the follicle lumen and follicle cell nucleus and the sources of the At-211 decay were the follicle lumen, follicle cells and nuclei.ResultsComparing the human, rat and mouse model, with At-211 homogeneously distributed within the follicle lumen. The calculated mean specific energy for the follicle cell nucleus was 0.17, 1.1 and 2.0 mGy, respectively. The corresponding single-hit mean specific energy was 370, 614 and 1252 mGy, respectively. Approximately 45 % of the alpha particles in a At-211 decay for the human model deposit all the kinetic energy within the follicle lumen, compared to 7 % for the rat model and <0.5 % for the mouse model.ConclusionThe results demonstrate the importance of taking the range of the alpha particles, and the spatial distribution of At-211 into account for dosimetric evaluation of thyroid exposure. The dosimetry for At-211 in the thyroid for different species cannot readily be translated between the species.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Microdosimetry
At-211
Thyroid follicles

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Josefsson, Ander ...
Forssell-Aronsso ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
European Journal ...
Av lärosätet
Göteborgs universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy