SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/269189"
 

Search: onr:"swepub:oai:gup.ub.gu.se/269189" > Challenges assessin...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Challenges assessing radiation risk in image-guided treatments-implications on optimisation of radiological protection

Almén, Anja (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Lundh, Charlotta, 1977 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Sahlgrenska University Hospital
Båth, Magnus, 1974 (author)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,Sahlgrenska University Hospital
 (creator_code:org_t)
2018-07-10
2018
English.
In: Journal of Radiological Protection. - : IOP Publishing. - 0952-4746 .- 1361-6498. ; 38:3, s. 1064-1076
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The present work explores challenges when assessing organ dose and effective dose concerning image-guided treatments. During these treatments considerable x-ray imaging is employed using technically advanced angiographic x-ray equipment. Thus, the radiation dose to organs and the related radiation risk are relatively difficult to assess. This has implications on the optimisation process, in which assessing radiation dose is one important part. In this study, endovascular aortic repair treatments were investigated. Organ dose and effective dose were assessed using Monte Carlo calculations together with a detailed specification of the exposure situation and patient size. The resulting normalised organ dose and effective dose with respect to kerma-area product for patient sizes and radiation qualities representative for the patient group were evaluated. The variability and uncertainty were investigated and their possible impact on optimisation of radiation protection was discussed. Exposure parameters, source to detector distances etc varied between treatments and also varied between image acquisitions during one treatment. Thus the derived normalised organ dose and effective dose exhibited a large range of values depending greatly on used exposure parameters and patient configuration. The derived normalised values for effective dose varied approximately between 0.05 and 0.30 mSv per Gy.cm(2) when taking patient sizes and exposure parameters into consideration, the values for organ doses exhibited even larger variation. The study shows a possible systematic error for derived organ doses and effective dose up to a factor of 7 if detailed exposure or patient characteristics are not known and/or not taken into consideration. The intra-treatment variability was also substantial and the normalised dose values varied up to a factor of 2 between image acquisitions during one treatment. The study shows that the use of conversion factors that are not adapted to the clinic can cause the radiation dose to be exaggerated or underestimated considerably. A conclusion from the present study is that the systematic error could be large and should be estimated together with random errors. A large uncertainty makes it difficult to detect true differences in radiation dose between methods and technology-a prerequisite for optimising radiation protection for image-guided treatments.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

radiation protection
patient dose
radiation risk
EVAR
image-guided procedures
endovascular aneurysm repair
hybrid operating-room
interventional
radiology
dose-reduction
aortic repair
exposure
patient
program
evar
technology
Environmental Sciences & Ecology
Public
Environmental & Occupational
Health
Nuclear Science & Technology
Radiology
Medical Imaging
nmark
v32
p19

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Almén, Anja
Lundh, Charlotta ...
Båth, Magnus, 19 ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Journal of Radio ...
By the university
University of Gothenburg
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view