SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:gup.ub.gu.se/290120"
 

Search: onr:"swepub:oai:gup.ub.gu.se/290120" > Immediate loading o...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Cannizzaro, Gioacchino (author)

Immediate loading of one (fixed-on-1) versus two (fixed-on-2) implants placed flapless supporting mandibular screw-retained cross-arch fixed prostheses: 10-month results from an explanatory randomised controlled trial.

  • Article/chapterEnglish2019

Publisher, publication year, extent ...

  • 2019

Numbers

  • LIBRIS-ID:oai:gup.ub.gu.se/290120
  • https://gup.ub.gu.se/publication/290120URI

Supplementary language notes

  • Language:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • To evaluate the outcome of one (fixed-on-1, Fo1) versus two (fixed-on-2, Fo2) implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses.Twenty patients with edentulous or to be rendered edentulous mandibles were randomised to the Fo1 group (10 patients who received three intraforaminal implants but only the mesial implant was actually loaded) and to the Fo2 group (10 patients who received two intraforaminal implants) according to a parallel-group design. To be immediately loaded implants had to be inserted with a minimum torque of 60 Ncm. Outcome measures were prosthesis and implant failures, complications and patient satisfaction for function and aesthetics evaluated up to 10 months post-loading.Flaps were raised in three patients of the Fo1 group and one of the Fo2 group. Two prostheses in each group were delayed loaded at 2 and 3 months, because implants could not be inserted with a torque superior to 60 Ncm. Patients of the Fo2 group received prostheses with 12 teeth whereas Fo1 patients with 8 or 10 teeth. Ten months after loading no drop-out or implant failure occurred, but one Fo2 prosthesis had to be remade because the patient complained it was too short (risk difference = 0.1; 95% CI: -0.19 to 0.40; Fisher's exact test P = 1.000). Three patients were affected by complications in each group (risk difference = 0.0; 95% CI: -0.359 to 0.359; Fisher's exact test; P = 1.000). There were no statistically significant differences for prosthetic failures and complications between groups. Four months after loading, patients of the Fo1 group were less satisfied for function than those of the Fo2 group (difference between the medians [Hodges-Lehmann estimation] = 1; 95% CI: 0 to 2; P = 0.043). No differences were observed for aesthetics (difference between the medians [Hodges-Lehmann estimation] = 0; 95% CI: -1 to 0; P = 0.481), and two Fo1 patients would not undergo the same procedure again (difference in proportions: 0.2; 95% CI: -0.11 to 0.51; P = 0.474).Preliminary results suggest that immediately loaded cross-arch screw-retained fixed prostheses with 8 to 10 teeth can be supported by only one dental implant at least up to 10 months post-loading; however, the clinical application and usefulness of such a procedure remains questionable.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Viola, Paolo (author)
  • Ippolito, Daniela Rita (author)
  • Esposito, Marco,1965Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials(Swepub:gu)xespom (author)
  • Göteborgs universitetInstitutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap (creator_code:org_t)

Related titles

  • In:International journal of oral implantology (New Malden, London, England)12:1, s. 89-1022631-6439

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Cannizzaro, Gioa ...
Viola, Paolo
Ippolito, Daniel ...
Esposito, Marco, ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Medical Biotechn ...
and Biomaterials Sci ...
Articles in the publication
International jo ...
By the university
University of Gothenburg

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view