Is there a reduction in risk of revision when 36-mm heads instead of 32 mm are used in total hip arthroplasty for patients with proximal femur fractures?: A matched analysis of 5,030 patients with a median of 2.5 years’ follow-up between 2006 and 2016 in the Nordic Arthroplasty Register Association
-
- Tsikandylakis, Georgios (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
-
- Kärrholm, Johan, 1951 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
-
Hallan, G. (author)
-
show more...
-
Furnes, O. (author)
-
Eskelinen, A. (author)
-
Mäkelä, K. (author)
-
Pedersen, A. B. (author)
-
Overgaard, S. (author)
-
- Mohaddes, Maziar, 1974 (author)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för ortopedi,Institute of Clinical Sciences, Department of Orthopaedics
-
show less...
-
(creator_code:org_t)
- 2020-04-14
- 2020
- English.
-
In: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 91:4, s. 401-407
- Related links:
-
https://www.tandfonl...
-
show more...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Background and purpose — 32-mm heads are widely used in total hip arthroplasty (THA) in Scandinavia, while the proportion of 36-mm heads is increasing as they are expected to increase THA stability. We investigated whether the use of 36-mm heads in THA after proximal femur fracture (PFF) is associated with a lower risk of revision compared with 32-mm heads. Patients and methods — We included 5,030 patients operated with THA due to PFF with 32- or 36-mm heads from the Nordic Arthroplasty Register Association database. Each patient with a 36-mm head was matched with a patient with a 32-mm head, using propensity score. The patients were operated between 2006 and 2016, with a metal or ceramic head on a polyethylene bearing. Cox proportional hazards models were fitted to estimate the unadjusted and adjusted hazard ratio (HR) with 95% confidence intervals (CI) for revision for any reason and revision due to dislocation for 36-mm heads compared with 32-mm heads. Results — 36-mm heads had an HR of 0.9 (CI 0.7–1.2) for revision for any reason and 0.8 (CI 0.5–1.3) for revision due to dislocation compared with 32-mm heads at a median follow-up of 2.5 years (interquartile range 1–4.4). Interpretation — We were not able to demonstrate any clinically relevant reduction of the risk of THA revision for any reason or due to dislocation when 36-mm heads were used versus 32-mm. Residual confounding due to lack of data on patient comorbidities and body mass index could bias our results. © 2020, © 2020 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Ortopedi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Orthopaedics (hsv//eng)
Publication and Content Type
- ref (subject category)
- art (subject category)
Find in a library
To the university's database
- By the author/editor
-
Tsikandylakis, G ...
-
Kärrholm, Johan, ...
-
Hallan, G.
-
Furnes, O.
-
Eskelinen, A.
-
Mäkelä, K.
-
show more...
-
Pedersen, A. B.
-
Overgaard, S.
-
Mohaddes, Maziar ...
-
show less...
- About the subject
-
- MEDICAL AND HEALTH SCIENCES
-
MEDICAL AND HEAL ...
-
and Clinical Medicin ...
-
and Orthopaedics
- Articles in the publication
-
Acta Orthopaedic ...
- By the university
-
University of Gothenburg