Sökning: onr:"swepub:oai:gup.ub.gu.se/61353" >
A descriptive study...
A descriptive study on retrieved non-threaded and threaded implant designs
-
- Bolind, Pia, 1953 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna,Institute of Surgical Sciences
-
- Johansson, Carina B., 1955 (författare)
- Örebro universitet,Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna,Institute of Surgical Sciences,Hälsovetenskapliga institutionen
-
Becker, W. (författare)
-
visa fler...
-
Langer, L. (författare)
-
Sevetz, E. B., Jr. (författare)
-
- Albrektsson, Tomas, 1945 (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för de kirurgiska disciplinerna, Avdelningen för biomaterialvetenskap,Institute of Surgical Sciences, Department of Biomaterials
-
visa färre...
-
(creator_code:org_t)
- 2005-04-27
- 2005
- Engelska.
-
Ingår i: Clinical oral implants research. - : Wiley. - 0905-7161 .- 1600-0501. ; 16:4, s. 447-55
- Relaterad länk:
-
https://gup.ub.gu.se...
-
visa fler...
-
https://doi.org/10.1...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- OBJECTIVES: In the light microscope compare the amount of bone saucerization for non-threaded cylindrical and threaded implant designs in retrieved samples from patients. MATERIAL AND METHOD: Consecutively received retrieved oral implants from 117 patients, whereof 85 non-threaded cylindrical and 85 Branemark implants, have been included in the study. For 75 non-threaded cylindrical and 46 Branemark implants was the entire implant length available for calculation. Undecalcified ground sections were investigated in the light microscope with calculation of percentage of implant length coronal to the first bone-implant contact and percentage of bone to implant contact. RESULTS: Mean value for implant length coronal to first bone-implant contact was 65%, standard error of the mean (SEM) 3 (range 0-100%), for non-threaded cylindrical implants and 43%, SEM 6 (range 0-100%) for Branemark implants. Mean values of bone contact along the entire implant length was 23%, SEM 2 (range 0-65%), for the non-threaded cylindrical implants and 33%, SEM 5 (range 0-93%) for the Branemark implants. CONCLUSION: Within the limitations of this retrospective, retrieval study non-threaded cylindrical implants demonstrated a greater bone saucerization when evaluated in the light microscope.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
Nyckelord
- Adult
- Aged
- Alveolar Bone Loss/pathology
- Alveolar Process/pathology
- Coated Materials
- Biocompatible/chemistry
- *Dental Implants
- *Dental Prosthesis Design
- Dental Restoration Failure
- Durapatite/chemistry
- Female
- Humans
- Male
- Middle Aged
- Osseointegration
- Prosthesis-Related Infections/pathology
- Retrospective Studies
- Surface Properties
- Titanium/chemistry
- Medicine
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas