SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:gup.ub.gu.se/83915"
 

Sökning: onr:"swepub:oai:gup.ub.gu.se/83915" > The use of virtual ...

The use of virtual reality for training in carotid artery stenting: a construct validation study

Berry, Max, 1969 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
Reznick, Richard (författare)
Lystig, Ted (författare)
visa fler...
Lönn, Lars, 1956 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper,Institute of Clinical Sciences
visa färre...
 (creator_code:org_t)
2008-09-01
2008
Engelska.
Ingår i: Acta Radiologica. - : SAGE Publications. - 1600-0455 .- 0284-1851. ; 49:7, s. 801-5
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Given that carotid artery stenosis (CAS) intervention is procedurally difficult, possesses an extensive learning curve, and involves a grave list of potential complications, construct validation of new non-clinical training devices is of increasing importance. Purpose: To evaluate the construct validity of the Procedicus-Virtual Interventional Simulator Trainer (Procedicus-VIST) and its use as a training tool. Material and Methods: Sixteen interventionalists (15 males, one female; mean interventional radiology [IR] experience >11 years) and 16 medical students (15 males, one female; no IR experience) received 1 hour of didactic instruction followed by an hour of familiarization training. Subjects then attempted to complete a carotid artery stenting procedure within 1 hour while their performance metrics were recorded. All participants completed a qualitative exit survey of subjective parameters using a visual analog scale. Results: Procedure and fluoroscopic time was 8.7 and 8.7 min greater in the novice group (P=0.0066 and P=0.0031), respectively. There were no significant differences in performances between the two groups in the remaining metrics of cine loops (number recorded), tool/vessel ratio, coverage percentage, and placement accuracy or residual stenosis. Contrast measurement metrics were found to be too imprecise for statistical analysis. Experienced and novice opinions differed significantly for six of 10 subjective parameters. No statistically significant difference in video-gaming habits was demonstrated. Conclusion: With the exception of the metrics of performance time and fluoroscopic use, construct validity of the Procedicus-VIST carotid metrics were not confirmed. Virtual reality simulation as a training method was valued more by novices than by experienced interventionalists.

Nyckelord

carotid artery stenting
education
endovascular surgery
interventional radiology
objective assessment
simulator training
virtual reality

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy