Anmärkningar
-
Introduction: Assay discrepancy in factor VIII activity between the one-stage and the chromogenic assays has been described in approximately one third of patients with non-severe haemophilia A. Whether assay discrepancy may also occur in patients with haemophilia B remains unknown. Aim: This study compared the results from the one-stage and the chromogenic assays in patients with haemophilia B. Methods: Plasma samples from patients with haemophilia B attending the haemophilia centre in Malmö, Sweden, were collected after a wash-out period of more than 7 days and analysed with both assays. Results: Fifty samples from 36 patients were analysed. No discrepancy was found in patients with severe haemophilia B. Among the 44 plasma samples from patients with non-severe disease, 15 showed a twofold or greater difference between the results of the two methods, with the chromogenic method presenting the higher value (mean FIX:Cone-stage 0.02 vs. FIX:Cchromo 0.06 IU mL-1). Of these 15 samples, 14 were from seven individuals from five families with the same mutated amino acid at the N-terminal cleaving site of the activation peptide (FIX: c.572G>A; p.Arg191His or FIX: c.571C>T; p.Arg191Cys). These mutations were not observed in any patients with non-discrepant results. The reported bleeding frequency for these patients was low and indicative of a mild bleeding phenotype. Conclusion: Our findings imply that assay discrepancy occurs for factor IX activity and that both type of assays are needed for a correct diagnosis and classification of haemophilia B. The underlying mechanism by which the mutation influences the assays remains to be determined.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Strandberg, K.Skåne University Hospital(Swepub:lu)klke-kst
(författare)
-
Rosén, S.
(författare)
-
Ljung, R.Lund University,Lunds universitet,Pediatrik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Pediatrisk hematologi,Forskargrupper vid Lunds universitet,Paediatrics (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Paediatric Haematology Research Unit,Lund University Research Groups,Skåne University Hospital(Swepub:lu)pedi-rlj
(författare)
-
Astermark, J.Skåne University Hospital(Swepub:lu)medf-jas
(författare)
-
Skåne University HospitalPediatrik, Lund
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Haemophilia: Wiley23:4, s. 620-6271351-8216
Internetlänk
Hitta via bibliotek
Till lärosätets databas