SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:0bd2e5d7-b8e4-40c6-902b-135e50e6864b"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:0bd2e5d7-b8e4-40c6-902b-135e50e6864b" > Influence of altern...

Influence of alternating V-rows tube layout on thermal-hydraulic characteristics of twisted elliptical tube heat exchangers

Gu, Huaduo (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,Southeast University
Chen, Yaping (författare)
Southeast University
Sundén, Bengt (författare)
Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Other operations, LTH,Faculty of Engineering, LTH,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Wu, Jiafeng (författare)
Southeast University
Song, Ning (författare)
Southeast University
Su, Jindong (författare)
Southeast University
visa färre...
 (creator_code:org_t)
Elsevier BV, 2020
2020
Engelska.
Ingår i: International Journal of Heat and Mass Transfer. - : Elsevier BV. - 0017-9310. ; 159
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An innovative alternating V-rows triangular tube layout was devised for the twisted elliptical tube heat exchangers to enhance heat transfer between adjacent tubes. Under the same tube circumference, altogether eleven twisted elliptical tube heat exchangers with two tube layouts, diverse aspect ratios of twisted elliptical tubes and different twisted pitches were constructed and simulated, including five coupling-vortex schemes, five parallel-vortex schemes and a smooth round tube scheme R10.8. Water with constant physical properties was adopted as the working fluid. Shell-side Reynolds number varies from 2000 to 10,000. The results show that the concurrent flow and the irregular channel in coupling-vortex schemes, and the larger aspect ratio and the smaller twisted pitch of twisted elliptical tubes help intensify turbulence and secondary flow. Compared with R10.8, the averaged Nu and Nu·f−1/3 of coupling-vortex scheme C14.2S50 are improved by 132.8% and 47.1%, respectively. Under shorter twisted pitch, smaller aspect ratio and lower Reynolds number, coupling-vortex schemes can acquire superior heat transfer capability than corresponding parallel-vortex schemes but will not increase manufacturing cost. Compared with P12.3S50, the maximum and averaged Nu of C12.3S50 are increased by 9.5% and 7.8% while the maximum and averaged Nu·f−1/3 are increased by 6.4% and 4.9%.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Alternating V-rows triangle tube layout
Coupling-vortex
Heat transfer enhancement
Spiral flow
Twisted elliptical tube heat exchangers

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gu, Huaduo
Chen, Yaping
Sundén, Bengt
Wu, Jiafeng
Song, Ning
Su, Jindong
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
International Jo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy