Reproducibility of ...
-
Drake, Anna MariaLund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
(författare)
Reproducibility of isokinetic ankle dorsiflexor strength and fatigue measurements in healthy older subjects.
- Artikel/kapitelEngelska2007
Förlag, utgivningsår, omfång ...
Nummerbeteckningar
-
LIBRIS-ID:oai:lup.lub.lu.se:1f1a5bd1-b8ea-41e0-9fce-4018ac2b6ad9
-
https://lup.lub.lu.se/record/1142852URI
-
https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-14202URI
-
https://doi.org/10.3233/IES-2007-0282DOI
Kompletterande språkuppgifter
-
Språk:engelska
-
Sammanfattning på:engelska
Ingår i deldatabas
Klassifikation
-
Ämneskategori:art swepub-publicationtype
-
Ämneskategori:ref swepub-contenttype
Anmärkningar
-
Upprättat; 2007; 20071203 (andbra)
-
The aim of this study was to determine the test-retest (two occasions seven days part) reproducibility of isokinetic (Biodex) concentric (CON) and eccentric (ECC) ankle dorsiflexor strength and fatigue measurements in older subjects using several statistical methods. Thirty healthy men (n=15) and women (n=15) aged between 70 and 85 years participated in the study. To determine the reproducibility of strength measurements, the 30 individuals performed three maximal CON and ECC contractions at 30°/s and 90°/s. The intraclass correlation coefficient (ICC_{2.1}) for CON and ECC strength measurements was high and ranged from 0.94 to 0.98. Bland & Altman graphs and analyses indicted no systematic bias. The standard error of measurement (SEM), representing the smallest change that indicates a real improvement (or deterioration) for a group of individuals, was small (< 2.3 Nm). The smallest real difference (SRD), representing the smallest detectable change that indicates a real improvement (or deterioration) for a single subject, was also small ('error bands' from −7.2 Nm to 5.6 Nm). A high correlation (Pearson's r > 0.94) between CON peak torque at 30°/s and 90°/s, as well as ECC peak torque at 30°/s and 90°/s, suggested that any of these two velocities could be used as a reference. To determine the reproducibility of fatigue measurements, 28 of the 30 individuals performed 50 maximal CON contractions at 60°/s. Reproducibility of the loss in work (work fatigue) and the relative loss in peak torque, comparing the first three to the last three contractions (3-3), was determined and the ICC was 0.71 and 0.60, respectively. In addition, the SEM was small (< 8.4%) and the 'error bands' to define the SRD for a single subject were also small (from −23.5% to 24.5%). In conclusion, these values indicate small measurement errors and thus provide a clinically acceptable basis for testing ankle dorsiflexion strength and fatigue of the dominant side in healthy older people.
Ämnesord och genrebeteckningar
Biuppslag (personer, institutioner, konferenser, titlar ...)
-
Lexell, JanLuleå tekniska universitet,Lund University,Lunds universitet,Neurokirurgi,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Neurosurgery,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Department of Clinical Sciences, Division of Rehabilitation Medicine, Lund University, Lund, Sweden(Swepub:ltu)janlex
(författare)
-
Holmbäck, Anna MariaDepartment of Health Sciences, Division of Physical Therapy, Lund University, Lund, Sweden
(författare)
-
Människan i rörelse: hälsa och rehabiliteringForskargrupper vid Lunds universitet
(creator_code:org_t)
Sammanhörande titlar
-
Ingår i:Isokinetics and Exercise Science15:4, s. 263-2701878-59130959-3020
Internetlänk
Hitta via bibliotek
Till lärosätets databas