SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:3d727230-bef2-472c-b6e7-b2e250d9a393"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:3d727230-bef2-472c-b6e7-b2e250d9a393" > Current best estima...

Current best estimates of beam quality correction factors for reference dosimetry of clinical proton beams

Palmans, Hugo (författare)
MedAustron,National Physical Laboratory, UK
Lourenço, Ana (författare)
University College London,National Physical Laboratory, UK
Medin, Joakim (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
visa fler...
Vatnitsky, Stanislav (författare)
MedAustron
Andreo, Pedro (författare)
Karolinska University Hospital
visa färre...
 (creator_code:org_t)
2022-09-29
2022
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 67:19
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective. To review the currently available data on beam quality correction factors, kQ, for ionization chambers in clinical proton beams and derive their current best estimates for the updated recommendations of the IAEA TRS-398 Code of Practice. Approach. The reviewed data come from 20 publications from which kQ values can be derived either directly from calorimeter measurements, indirectly from comparison with other chambers or from Monte Carlo calculated overall chamber factors, fQ. For cylindrical ionization chambers, a distinction is made between data obtained in the centre of a spread-out Bragg peak and those obtained in the plateau region of single-energy fields. For the latter, the effect of depth dose gradients has to be considered. To this end an empirical model for previously published displacement correction factors for single-layer scanned beams was established, while for unmodulated scattered beams experimental data were used. From all the data, chamber factors, fQ, and chamber perturbation correction factors, pQ, were then derived and analysed. Main results. The analysis showed that except for the beam quality dependence of the water-to-air mass stopping power ratio and, for cylindrical ionization chambers in unmodulated beams, of the displacement correction factor, there is no remaining beam quality dependence of the chamber perturbation correction factors pQ. Based on this approach, average values of the beam quality independent part of the perturbation factors were derived to calculate kQ values consistent with the data in the literature. Significance. The resulting data from this analysis are current best estimates of kQ values for modulated scattered beams and single-layer scanned beams used in proton therapy. Based on this, a single set of harmonized values is derived to be recommended in the update of IAEA TRS-398.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

beam quality correction factor
IAEA TRS-398 update
ionization chamber
proton beam
reference dosimetry

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Palmans, Hugo
Lourenço, Ana
Medin, Joakim
Vatnitsky, Stani ...
Andreo, Pedro
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Physics in Medic ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy