Sökning: onr:"swepub:oai:lup.lub.lu.se:56075a93-5eac-4f37-ae27-5b5f2c8e07d1" >
Optimization of ene...
Optimization of energy and directional response of a small 4π silicon dosemeter for quality control of CT/CBCT-units – A 3D CAD, Monte-Carlo, AM approach
-
- Herrnsdorf, L. (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
- Andersson, M. (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Medical Radiation Physics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
- Gunnarsson, M. (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
visa fler...
-
- Mattsson, S. (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2020
- 2020
- Engelska.
-
Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043. ; 158
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A 4π radiation dosemeter for use in medical radiology was designed. It is based on a solid state silicon detector, a sensor wafer, a flex card, a 3D plastic holder and a spherical stainless steel filter with a distribution of holes around the detector. The detector is attached to the wafer using only low Z material. To achieve an energy and directional response which is as uniform as possible for various radiation qualities and beam directions, the filter was designed using a series of Monte Carlo calculations. The energy filter and its hole pattern were created using Additive Manufacturing (AM) in the form of metal 3D printing. The functionality of the dosemeter was designed to fulfill the quality criteria of a combined energy and angular dependence of less than 5% for the IEC beam qualities RQR and RQT in the range of 65–145 kV. This is a major improvement to the existing solutions that may need software corrections to be used for the same beam quality range.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas