SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:lup.lub.lu.se:7ab1a845-fbce-48ab-83ba-af5522c40f90"
 

Search: onr:"swepub:oai:lup.lub.lu.se:7ab1a845-fbce-48ab-83ba-af5522c40f90" > Brain Tumors: Evalu...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Brain Tumors: Evaluation of Perfusion Using 3D-FSE-Pseudo-Continuous Arterial Spin Labeling

Järnum, Hanna (author)
Aarhus University Hospital
Knutsson, Linda (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,MR Physics,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Lund University Research Groups
Larsson, Elna-Marie (author)
Uppsala universitet,Uppsala University,Enheten för radiologi
show more...
Hayat, M.A. (editor)
show less...
 (creator_code:org_t)
2011-05-10
2011
English.
In: Tumors of the Central Nervous system. - Dordrecht : Springer Netherlands. - 9789400713987 - 9789400713994 ; 3, s. 135-142
  • Book chapter (peer-reviewed)
Abstract Subject headings
Close  
  • In this chapter, the advantages and disadvantages of 3D fast spin echo (FSE) pCASL as a measure of brain tumor perfusion are reviewed. In addition, we compare pCASL with other perfusion techniques and discuss future ASL approaches. A prospective study of 28 patients with contrast-enhancing brain tumors was performed at 3 T using dynamic susceptibility contrast (DSC) MRI and pCASL. The visual qualitative evaluation of signal enhancement in tumor was scored from 0 to 3 (0 = no signal enhancement compared with white matter (WM), 3 = pronounced signal enhancement with similar or higher signal intensity than in gray matter (GM)/basal ganglia). The extent of susceptibility artifacts in the tumor was scored from 0 to 2 (0 = no susceptibility artifacts, 2 = extensive susceptibility artifacts (maximum diameter >2 cm). Absolute ASL cerebral blood flow (CBF) values in tumor, GM, WM, and cerebellum were also measured. Using normalized tumor blood flow values (ASL nTBF, DSC nTBF), tumor-to-healthy tissue perfusion ratios were calculated by dividing the mean value of tumor ROI by the mean value in ROIs in the two cerebellar hemispheres. ASL had in comparison with DSC-MRI both a lower signal enhancement score (p = 0.02) and a lower susceptibility artifact score (p < 0.01). The highest absolute ASL CBF values were measured in tumor tissue and the lowest in WM. There was a good correlation between DSC nTBF and ASL nTBF values, with a correlation coefficient of 0.82.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publication and Content Type

kap (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Järnum, Hanna
Knutsson, Linda
Larsson, Elna-Ma ...
Hayat, M.A.
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Articles in the publication
Tumors of the Ce ...
By the university
Lund University
Uppsala University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view