Sökning: onr:"swepub:oai:lup.lub.lu.se:92249037-b020-467b-ba1b-2cb8009787a4" >
Étude des performan...
Étude des performances et optimisation de la conception de nouveaux compresseurs rotatifs à palettes coulissantes à cylindre rotatif
-
- Gu, Huaduo (författare)
- Southeast University, Nanjing,City University of Hong Kong
-
- Ye, Fanghua (författare)
- Nanchang University
-
- Chen, Yaping (författare)
- Southeast University, Nanjing
-
visa fler...
-
- Wu, Jiafeng (författare)
- Southeast University, Nanjing
-
- Li, Weihong (författare)
- City University of Hong Kong
-
- Sundén, Bengt (författare)
- Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,LTH profilområde: Nanovetenskap och halvledarteknologi,LTH profilområden,Other operations, LTH,Faculty of Engineering, LTH,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,LTH Profile areas,Faculty of Engineering, LTH
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2022
- 2022
- Franska 11 s.
-
Ingår i: International Journal of Refrigeration. - : Elsevier BV. - 0140-7007. ; 142, s. 137-147
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Novel rotating-cylinder sliding vane rotary compressors (RC-SVRCs) are promising machines in energy conversion systems due to extremely low friction. However, three-dimensional visual investigations on geometrical optimizations of RC-SVRCs are highly limited. Besides, most flow mechanisms and leakage flow affected by geometric structures have not been fully revealed yet. Therefore, the sliding vane number, gap heights at vane tips and length-to-diameter ratio are numerically studied in this work. The results show that more sliding vanes (4∼12) lead to more uniform flow and temperature fields, lower mass flow rates and outlet temperature, less leakage between rotor and rotating cylinder. The mass flow rate, leakage mL1 between rotor and cylinder and leakage mL2 at vane tip of 8-sliding-vane scheme are 2.944 × 10−2, 9.949 × 10−4 and 3.692 × 10−5 kg·s−1, respectively. Gap height at vane tips has vital effects on flow fields. As the gap increases (0.01∼0.05 mm), mass flow rate and isentropic efficiency are decreased by 12.68% and 18.26%, the outlet temperature, leakage mL1 and mL2 are increased by 91.5 K, 69.60% and 22 times, respectively. High-temperature areas and leakage flow increase with the increase of cylinder length, which is recommended no longer than 0.6 diameters. This work allows making recommendations for designing RC-SVRCs.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)
Nyckelord
- Comprehensive performance investigation
- Design optimization
- Flow mechanism
- Numerical investigation
- Rotating-cylinder sliding vane rotary compressor
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas