Target definition in radiotherapy of prostate cancer using magnetic resonance imaging only workflow
-
- Gunnlaugsson, Adalsteinn (författare)
- Skåne University Hospital
-
- Persson, Emilia (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
- Jamtheim Gustafsson, Christian (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Radiotherapy Physics,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
visa fler...
-
- Kjellén, Elisabeth (författare)
- Skåne University Hospital
-
- Ambolt, Petra (författare)
- Skåne University Hospital
-
- Engelholm, Silke (författare)
- Skåne University Hospital
-
- Nilsson, Per (författare)
- Skåne University Hospital
-
- Olsson, Lars E (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2019
- 2019
- Engelska 3 s.
-
Ingår i: Physics and imaging in radiation oncology. - : Elsevier BV. - 2405-6316. ; 9, s. 89-91
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
http://phiro.science...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- In magnetic resonance (MR) only radiotherapy, the target delineation needs to be performed without computed tomography (CT). We investigated in thirteenpatients with prostate cancer, how the clinical target volume (CTV) was affected, when the target delineation procedure was changed from using both CT and MRimages to using MR images only. The mean volume of the CTVCT/MR was 61.0 cm3 as compared to 49.9 cm3 from MR-only based target delineation, corresponding toan average decrease of 18%. Our results show that CTVMR-only was consistently smaller than CTVCT/MR, which has to be taken into consideration before clinicalcommissioning of MR-only radiotherapy.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)