Optimizing conventional cardiac MRI in the rabbit at 0.3 T

Malmgren, N (författare)
Laurin, Sven (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Ståhlberg, Freddy (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medicinsk strålningsfysik, Lund,Institutionen för kliniska vetenskaper, Lund,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Medical Radiation Physics, Lund,Department of Clinical Sciences, Lund
visa fler...
Holtås, Stig (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Diagnostic Radiology, (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
1993
1993
Engelska.
Ingår i: Pediatric Radiology. - 1432-1998. ; 23:6, s. 439-441
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to define the most efficient way of performing cardiac MRI for anatomic information in small experimental animals, using a vertical magnetic field with a strength of 0.3 T (FONAR beta-3000M). This information may be used to improve cardiac MRI in infants and small children, since the size of a rabbit is considered comparable to that of a neonate. Experimental axial cardiac MRI studies were performed in a rabbit under general anesthesia in order to study the effects on image quality of changing various imaging parameters. These are ECG-gating, number of excitations (averages), number of warp levels, echo time (TE) and repetition time (TR). The effects of changing the size of the field of view (FOV), the slice thickness and the phase-encoding direction were also studied. We found that ECG-gating was crucial and that three excitations, TE 16 ms, and 257 vertical phase-encoding warp levels were adequate. Five-millimeter slice thickness and FOV 20 cm were preferred.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Malmgren, N
Laurin, Sven
Ståhlberg, Fredd ...
Holtås, Stig
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Pediatric Radiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy