Search: onr:"swepub:oai:lup.lub.lu.se:ba51d295-72e0-45e7-9148-91ea967b8d71" >
Optimised versus st...
Optimised versus standard automated peritoneal dialysis regimens pilot study (OptiStAR) : A randomised controlled crossover trial
-
- Bergling, Karin (author)
- Lund University,Lunds universitet,Njurmedicin,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Nephrology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
- de Arteaga, Javier (author)
- Hospital Privado Universitario de Córdoba
-
- Ledesma, Fabián (author)
- Hospital Privado Universitario de Córdoba
-
show more...
-
- Öberg, Carl M. (author)
- Lund University,Lunds universitet,Njurmedicin,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Njurfysiologi och peritonealdialys,Forskargrupper vid Lunds universitet,Nephrology,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine,Renal physiology and peritoneal dialysis,Lund University Research Groups,Skåne University Hospital
-
show less...
-
(creator_code:org_t)
- 2022-01-17
- 2022
- English.
-
In: Peritoneal Dialysis International. - : SAGE Publications. - 0896-8608. ; 42:6, s. 615-621
- Related links:
-
http://dx.doi.org/10... (free)
-
show more...
-
https://journals.sag...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
show less...
Abstract
Subject headings
Close
- Background: The continuous global rise of end-stage kidney disease creates a growing demand of economically beneficial home-based kidney replacement therapies such as peritoneal dialysis (PD). However, undesirable absorption and exposure of peritoneal tissues to glucose remain major limitations of PD. Methods: We compared a reference (standard) automated PD regimen 6 × 2 L 1.36% glucose (76 mmol/L) over 9 h with a novel, theoretically glucose sparing (optimised) prescription consisting of ‘ultrafiltration cycles’ with high glucose strength (126 mmol/L) and ‘clearance cycles’ with ultra-low, physiological glucose (5 mmol/L) for approximately 40% of the treatment time. Twenty-one prevalent PD patients underwent the optimised regimen (7 × 2 L 2.27% glucose + 5 × 2 L 0.1% glucose over 8 h) and the standard regimen in a crossover fashion. Six patients were excluded from data analysis. Results: Median glucose absorption was 43 g (IQR 41–54) and 44 g (40–55) for the standard and optimised intervention, respectively (p = 1). Ultrafiltration volume, weekly Kt/V creatinine and urea were significantly improved during optimised interventions, while no difference in sodium removal was detected. Post hoc analysis showed significantly improved ultrafiltration efficiency (ml ultrafiltration per gram absorbed glucose) during optimised regimens. No adverse events were observed except one incidence of drain pain. Conclusion: Optimised treatments were feasible and well tolerated in this small pilot study. Despite no difference in absorbed glucose, results indicate possible improvements of ultrafiltration efficiency and small solute clearances by optimised regimens. Use of optimised prescriptions as glucose sparing strategy should be evaluated in larger study populations.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Urology and Nephrology (hsv//eng)
Keyword
- Automatic peritoneal dialysis
- glucose absorption
- metabolic cost
- peritoneal dialysis
- zero-glucose fluid
Publication and Content Type
- art (subject category)
- ref (subject category)
Find in a library
To the university's database