Sökning: onr:"swepub:oai:lup.lub.lu.se:bce55ca7-2c6b-4476-ba2d-a6991604ff21" >
Results from the fi...
Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry
-
- Bech, Martin (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Technical University of Munich
-
- Tapfer, Arne (författare)
- Technical University of Munich
-
- Velroyen, Astrid (författare)
- Technical University of Munich
-
visa fler...
-
- Yaroshenko, Andre (författare)
- Technical University of Munich
-
- Pauwels, Bart (författare)
- Bruker microCT
-
- Bruyndonckx, Peter (författare)
- Bruker microCT
-
- Liu, Xuan (författare)
- Bruker microCT
-
- Sasov, Alexander (författare)
- Bruker microCT
-
- Mohr, Jürgen (författare)
- Karlsruhe Institute of Technology
-
- Walter, Marco (författare)
- microworks GmbH
-
- Pfeiffer, Franz (författare)
- Technical University of Munich
-
Momose, Atsushi (redaktör/utgivare)
-
Yashiro, Wataru (redaktör/utgivare)
-
visa färre...
-
(creator_code:org_t)
- AIP, 2012
- 2012
- Engelska 7 s.
-
Ingår i: International Workshop on X-Ray and Neutron Phase Imaging with Gratings. - : AIP. - 1551-7616 .- 0094-243X. - 9780735410725 ; 1466, s. 130-136
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Preclinical
- Tomography
- X-ray Phase-contrast
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Bech, Martin
-
Tapfer, Arne
-
Velroyen, Astrid
-
Yaroshenko, Andr ...
-
Pauwels, Bart
-
Bruyndonckx, Pet ...
-
visa fler...
-
Liu, Xuan
-
Sasov, Alexander
-
Mohr, Jürgen
-
Walter, Marco
-
Pfeiffer, Franz
-
Momose, Atsushi
-
Yashiro, Wataru
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
International Wo ...
- Av lärosätet
-
Lunds universitet