Sökning: onr:"swepub:oai:lup.lub.lu.se:c6f0cd97-f093-457d-a557-c79b43d8ef47" >
Nephrogenic systemi...
Nephrogenic systemic fibrosis and gadolinium-based contrast media: updated ESUR Contrast Medium Safety Committee guidelines
-
Thomsen, Henrik S. (författare)
-
Morcos, Sameh K. (författare)
-
Almen, Torsten (författare)
-
visa fler...
-
Bellin, Marie-France (författare)
-
Bertolotto, Michele (författare)
-
Bongartz, Georg (författare)
-
Clement, Olivier (författare)
-
- Leander, Peter (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
-
Heinz-Peer, Gertraud (författare)
-
Reimer, Peter (författare)
-
Stacul, Fulvio (författare)
-
van der Molen, Aart (författare)
-
Webb, Judith A. W. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2012-08-04
- 2013
- Engelska.
-
Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 23:2, s. 307-318
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- To update the guidelines of the Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) on nephrogenic systemic fibrosis and gadolinium-based contrast media. Topics reviewed include the history, clinical features and prevalence of nephrogenic systemic fibrosis and the current understanding of its pathophysiology. The risk factors for NSF are discussed and prophylactic measures are recommended. The stability of the different gadolinium-based contrast media and the potential long-term effects of gadolinium in the body have also been reviewed. aEuro cent Clinical features, risk factors and prevention of nephrogenic systemic fibrosis are reviewed aEuro cent Patients with GFR below 30 ml/min/1.73 m (2) have increased risk of developing NSF aEuro cent Low stability gadolinium contrast media show the strongest association with NSF aEuro cent Following guidelines regarding gadolinium contrast agents minimises the risk of NSF aEuro cent Potential long-term harm from gadolinium accumulation in the body is discussed.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Nephrogenic systemic fibrosis
- Contrast media
- Gadolinium
- Renal
- insufficiency
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Thomsen, Henrik ...
-
Morcos, Sameh K.
-
Almen, Torsten
-
Bellin, Marie-Fr ...
-
Bertolotto, Mich ...
-
Bongartz, Georg
-
visa fler...
-
Clement, Olivier
-
Leander, Peter
-
Heinz-Peer, Gert ...
-
Reimer, Peter
-
Stacul, Fulvio
-
van der Molen, A ...
-
Webb, Judith A. ...
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
-
och Radiologi och bi ...
- Artiklar i publikationen
-
European Radiolo ...
- Av lärosätet
-
Lunds universitet