Sökning: onr:"swepub:oai:lup.lub.lu.se:dd8f4a30-2af1-42bf-909e-3050ebf0b908" >
Muscle blood flow i...
Muscle blood flow in cats: comparison of microdialysis ethanol technique with direct measurement
-
Hickner, R C (författare)
-
- Ekelund, Ulf (författare)
- Karolinska Institutet,Lund University,Lunds universitet,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Mellander, Stefan (författare)
- Lund University,Lunds universitet,Institutionen för experimentell medicinsk vetenskap,Medicinska fakulteten,Department of Experimental Medical Science,Faculty of Medicine
-
visa fler...
-
Ungerstedt, U (författare)
-
- Henriksson, J (författare)
- Karolinska Institutet
-
visa färre...
-
(creator_code:org_t)
- American Physiological Society, 1995
- 1995
- Engelska.
-
Ingår i: Journal of Applied Physiology. - : American Physiological Society. - 1522-1601 .- 8750-7587. ; 79:2, s. 638-647
- Relaterad länk:
-
http://jap.physiolog...
-
visa fler...
-
https://lup.lub.lu.s...
-
http://kipublication...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- A quantitative validation of the microdialysis ethanol technique was performed in cat gastrocnemius muscle. Six to eight microdialysis probes were inserted into the isolated muscle preparation and perfused (0.5-10.0 microliters/min) with Krebs-Henseleit buffer containing between 5 and 1,000 mmol/l ethanol. Skeletal muscle blood flow was held constant in the range of 4-99 ml.100 g-1.min-1 by a servo-controlled roller pump and was determined with the microdialysis ethanol technique as well as by timed collection of venous outflow. The ethanol concentration outflow-to-inflow ratio ([ethanol]collected dialysate/[ethanol]infused perfusion medium) decreased in a nonlinear fashion when microdialysis perfusion flow rates of 0.5 and 1.0 microliter/min were employed. However, a linear decrease was found between 4 and approximately 45 ml.100 g-1.min-1 (r = -0.92 to -0.99). The lower outflow-to-inflow ratio was at 4 ml.100 g-1.min-1 (i.e., due to a low probe perfusion flow rate or a large dialysis membrane), the greater the sensitivity of the method was. It is concluded that this nonradioactive technique provides a simple and valid method for determining nutritive blood flow in skeletal muscle.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Basic Medicine -- Physiology (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas