SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:f055f201-add7-48b0-a6f9-92417a8654a0"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:f055f201-add7-48b0-a6f9-92417a8654a0" > Comprehensive venti...

Comprehensive ventilation/perfusion SPECT

Palmer, John (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Bitzén, Ulrika (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Jonson, Björn (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Bajc, Marika (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 42:8, s. 1288-1294
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Lung scintigraphy is the primary tool for diagnostics of pulmonary embolism. A perfusion study is often complemented by a ventilation study. Intermediate probability scans are frequent. Our goal was to develop a fast method for tomographic ventilation and perfusion scintigraphy to improve the diagnostic value of lung scintigraphy. METHODS: SPECT was performed with a dual-head gamma camera. Acquisition parameters were determined using a thorax phantom. Ventilation tomography after inhalation of 30 MBq (99m)Tc-diethylenetriaminepentaacetate (DTPA) aerosol was, without patient movement, followed by perfusion tomography after an intravenous injection of 100 MBq (99m)Tc-labeled macroaggregated albumin (MAA). Total SPECT acquisition time was 20 min. (99m)Tc-DTPA clearance, calculated from initial and final SPECT projections, was used for correction of the ventilation projection set before iterative reconstruction of ventilation and perfusion. The ventilation background was subtracted from the perfusion tomograms. A normalized ventilation/perfusion quotient (V/P quotient) image set was calculated. The method was evaluated on a trial group of 15 patients. RESULTS: Ventilation and perfusion images had adequate quality and showed ventilation/perfusion (V/Q quotient) relationships more clearly than did planar images. Frontal and sagittal slices were superior to planar scintigraphy for characterization of embolized areas. The V/Q quotient was supportive, particularly in the patients with chronic obstructive pulmonary disease. CONCLUSION: Fast, high-quality, ventilation/perfusion SPECT with standard isotopes doses is feasible and may contribute to higher objectivity in evaluating lung embolism as well as other lung diseases. The costs for the procedure and patient care until diagnosis are low because of the comprehensive system for the study and, particularly, the short time for its completion.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

lung
perfusion
ventilation
lung embolism
tomography

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Palmer, John
Bitzén, Ulrika
Jonson, Björn
Bajc, Marika
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Nucle ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy