SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:30088eeb-24f7-4db5-895d-57b3dc073002"
 

Sökning: onr:"swepub:oai:research.chalmers.se:30088eeb-24f7-4db5-895d-57b3dc073002" > Determining the inf...

Determining the influence of LC2 and FA on the iodide diffusion coefficient of in seawater and sea sand concrete: A novel modified RIM test method

Liu, Jun (författare)
Shenzhen University
Liu, Jiaying (författare)
Shenzhen University
Cheng, Lei (författare)
Shenzhen University
visa fler...
Zhu, J. H. (författare)
Shenzhen University
Xing, F. (författare)
Shenzhen University
Fan, Xu (författare)
Shenzhen University
Tang, Luping, 1956 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Cement and Concrete Composites. - 0958-9465. ; 143
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A novel modified Rapid Iodide Migration (RIM) test method was used to determine the influence of LC2 and FA on iodide ion diffusion coefficient of seawater and sea sand concrete (SSC). A 0.1 mol/L AgNO3 solution was selected as the indicator to develop the colour of iodide in SSC, and a lowered mass fraction of NaI solution was selected to improve the RIM test. An X-Ray Fluorescence (XRF) test was employed to detect the feasibility of the modified RIM test. Additionally, the effects of the w/c ratio, the type and substitution rate of supplementary cementitious materials (SCMs), and the compressive strength on the iodide ion diffusion coefficient of SSC were studied using the modified RIM test. The results show that it is completely feasible to use AgNO3 solution as an indicator. A lower mass fraction of NaI solution not only does not change the iodide ion diffusion coefficient of concrete but also reduces the test cost by 77.46% when using a 5 wt% NaI solution. Moreover, using SCMs to replace cement, liking fly ash (FA) and calcined clay and limestone (LC2), significantly reduces the iodide ion permeability of SSC, especially the use of LC2. Furthermore, there is a nonlinear relationship between the compressive strength and the iodide ion diffusion coefficient of SSC. This work is beneficial for the promotion of the application of modified RIM tests in studies of concrete contaminated with chloride and can provide a theoretical basis for the application of seawater and sea sand in engineering practices.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Geoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Geotechnical Engineering (hsv//eng)

Nyckelord

LC2
Iodide ion diffusion coefficient
Fly ash
RIM test
Seawater and sea sand concrete

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy