Impact of Center Experience on Patient Radiation Exposure During Transradial Coronary Angiography and Percutaneous Intervention: A Patient-Level, International, Collaborative, Multi-Center Analysis

Simard, Trevor (författare)
Hibbert, Benjamin (författare)
Natarjan, Machu (författare)
visa fler...
Mercuri, Mathew (författare)
Hetherington, Simon (författare)
Wright, Robert (författare)
Delewi, Ronak (författare)
Piek, Jan (författare)
Lehmann, Ralf (författare)
Ruzsa, Zoltan (författare)
Lange, Helmut (författare)
Geijer, Håkan (författare)
Sandborg, Michael 1961- (författare)
Kansal, Vinay (författare)
Bernick, Jordan (författare)
Di Santo, Pietro (författare)
Pourdjabbar, Ali (författare)
Ramirez, Daniel (författare)
Chow, Benjamin (författare)
Chong, Aun (författare)
Labinaz, Marino (författare)
Le May, Michel (författare)
O’Brien, Edward (författare)
Wells, George (författare)
So, Derek (författare)
visa färre...
 (utgivare)
 (utgivare)
visa fler...
 (utgivare)
 (utgivare)
visa färre...
Wiley-Blackwell 2016
2016
Engelska.
Ingår i: Journal of the American Heart Association. - 2047-9980. ; 5:6
  • swepub:Mat__t
Abstract Ämnesord
Stäng  
  • Background-—The adoption of the transradial (TR) approach over the traditional transfemoral (TF) approach has been hampered by concerns of increased radiation exposure—a subject of considerable debate within the field. We performed a patient-level, multi-center analysis to definitively address the impact of TR access on radiation exposure. Methods and Results-—Overall, 10 centers were included from 6 countries—Canada (2 centers), United Kingdom (2), Germany (2), Sweden (2), Hungary (1), and The Netherlands (1). We compared the radiation exposure of TR versus TF access using measured dose-area product (DAP). To account for local variations in equipment and exposure, standardized TR:TF DAP ratios were constructed per center with procedures separated by coronary angiography (CA) and percutaneous coronary intervention (PCI). Among 57 326 procedures, we demonstrated increased radiation exposure with the TR versus TF approach, particularly in the CA cohort across all centers (weighted-average ratios: CA, 1.15; PCI, 1.05). However, this was mitigated by increasing TR experience in the PCI cohort across all centers (r=0.8; P=0.005). Over time, as a center transitioned to increasing TR experience (r=0.9; P=0.001), a concomitant decrease in radiation exposure occurred (r=0.8; P=0.006). Ultimately, when a center’s balance of TR to TF procedures approaches 50%, the resultant radiation exposure was equivalent. Conclusions-—The TR approach is associated with a modest increase in patient radiation exposure. However, this increase is  eliminated when the TR and TF approaches are used with equal frequency—a guiding principle for centers adopting the TR approach.

Ämnesord

Medical and Health Sciences  (hsv)
Clinical Medicine  (hsv)
Cardiac and Cardiovascular Systems  (hsv)
Medicin och hälsovetenskap  (hsv)
Klinisk medicin  (hsv)
Kardiologi  (hsv)

Nyckelord

coronary angiography
dose-area product
percutaneous coronary intervention
radial artery catheterisation
radiation
transradial

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy